
224
Adding Disk Enclosures to Increase Capacity
Adding Disk Enclosures to Increase Capacity
Scalability is an important part of the design of the HP SureStore E Disk Array FC60. The
capacity of the disk array can be increased in a variety of ways to meet growing storage
needs. See
"Adding Capacity to the Disk Array" on page 254
for more information on
scalability options.
Adding disk array enclosure(s) is the most effective way of significantly increasing the
capacity of the disk array. It is also the most involved. The following procedure describes
the process of adding disk enclosures to the disk array configuration.
Note
This procedure should be performed by properly trained personnel only.
General Rules for Adding Disk Enclosures to the Disk Array
•
Shutting Down the Disk Array - Adding one or more new disk enclosures requires
powering off the entire disk array. This will make all data on the disk array unavailable
during the expansion process.
•
Backing Up Data -All data on the disk array should be backed up to prevent data loss
should problems occur during the expansion.
•
Maintaining High Availability - Adding disk enclosures will typically require that you
convert existing disk enclosures from split-bus configuration to full-bus configuration.
This may result in more than one disk in a LUN being on the same channel. This will
necessitate moving disks to other enclosures following the expansion. For optimum
high-availability, there should never be no more than one disk from a LUN on each
channel.
•
Moving Disk Modules - When moving disks during the expansion, it is recommended
that disks be moved to the enclosure and slot that correspond to the original channel:ID
of the disk. For example, if the disk was originally installed in the slot corresponding to
channel 4, ID 1, it should be moved to the slot that corresponds to the same values
following the expansion. Although disks can be moved to any slot, maintaining the same
channel:ID simplifies LUN management.
Содержание Surestore Disk Array 12h - And FC60
Страница 16: ...16 ...
Страница 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Страница 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Страница 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Страница 68: ...68 Capacity Management Features ...
Страница 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Страница 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Страница 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Страница 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Страница 134: ...134 Topologies for Windows NT and Windows 2000 Figure 45 Four Host Single Hub Single Disk Array Non HA Topology ...
Страница 136: ...136 Topologies for Windows NT and Windows 2000 Figure 47 Four Host Single Switch Dual Disk Array Non HA Topology ...
Страница 138: ...138 Topologies for Windows NT and Windows 2000 Figure 48 Direct Connect Single Host Single Disk Array HA Topology ...
Страница 140: ...140 Topologies for Windows NT and Windows 2000 Figure 50 Four Host Dual Hub Dual Disk Array HA Topology ...
Страница 142: ...142 Topologies for Windows NT and Windows 2000 ...
Страница 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Страница 159: ...Installing the Disk Array FC60 159 Installation Figure 55 Enclosure EIA Positions for Legacy Cabinets ...
Страница 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Страница 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Страница 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Страница 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Страница 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Страница 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Страница 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Страница 358: ...358 Support Tools Manager ...
Страница 401: ...Controller Enclosure Modules 401 Removal and Replacement Figure 101 BBU Removal and Replacement ...
Страница 440: ...440 FCC Statements USA Only ...
Страница 466: ...466 Index ...