Disk Array High Availability Features
53
Produ
ct Des
c
ript
ion
pair. For highest data availability, each disk in the mirrored pair must be located in a
different enclosure.
When a disk fails, the disk array automatically uses the remaining disk of the mirrored pair
for data access. A RAID 0/1 LUN can survive the failure of multiple disks, as long as one
disk in each mirrored pair remains accessible. Until the failed disk is replaced (or a rebuild
on a global hot spare is completed), the LUN operates in degraded mode. While in degraded
mode, the LUN is susceptible to the failure of the second disk of the pair. If both disks fail
or become inaccessible simultaneously, the data on the LUN becomes inaccessible.
Figure 20
illustrates the distribution of data in a four-module RAID 0/1 LUN. The disk block
addresses in the stripe proceed sequentially from the first pair of mirrored disks (disks 1
and 2) to the second pair of mirrored disks (disks 3 and 4), then again from the first
mirrored disks, and so on.
Figure 20
RAID 0/1
LUN
RAID 3
RAID 3 uses parity to achieve data redundancy and disk striping to enhance performance.
Data is distributed across all but one of the disks in the RAID 3 LUN. The remaining disk is
used to store parity information for each data stripe. A RAID 3 LUN consists of three or
Содержание Surestore Disk Array 12h - And FC60
Страница 16: ...16 ...
Страница 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Страница 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Страница 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Страница 68: ...68 Capacity Management Features ...
Страница 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Страница 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Страница 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Страница 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Страница 134: ...134 Topologies for Windows NT and Windows 2000 Figure 45 Four Host Single Hub Single Disk Array Non HA Topology ...
Страница 136: ...136 Topologies for Windows NT and Windows 2000 Figure 47 Four Host Single Switch Dual Disk Array Non HA Topology ...
Страница 138: ...138 Topologies for Windows NT and Windows 2000 Figure 48 Direct Connect Single Host Single Disk Array HA Topology ...
Страница 140: ...140 Topologies for Windows NT and Windows 2000 Figure 50 Four Host Dual Hub Dual Disk Array HA Topology ...
Страница 142: ...142 Topologies for Windows NT and Windows 2000 ...
Страница 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Страница 159: ...Installing the Disk Array FC60 159 Installation Figure 55 Enclosure EIA Positions for Legacy Cabinets ...
Страница 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Страница 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Страница 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Страница 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Страница 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Страница 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Страница 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Страница 358: ...358 Support Tools Manager ...
Страница 401: ...Controller Enclosure Modules 401 Removal and Replacement Figure 101 BBU Removal and Replacement ...
Страница 440: ...440 FCC Statements USA Only ...
Страница 466: ...466 Index ...