
Topologies for HP-UX
113
T
opo
logy
and
Ar
ra
y
Pla
nnin
g
Table 9
Single-System Distance Topology Error Recovery
Failing
component
Continue
after failure
What happens and how to recover
Disk module
Yes
Applications continue to run on all supported RAID levels (RAID-
1, 0/1, and 5). The system administrator or service provider hot-
swaps the failed disk module.
Controller
module in
single-
controller
module array
(no high
availability)
No
The disk array fails. The system administrator or service provider
replaces the controller module and the system administrator
restarts the operating system and applications.
Controller
module in
dual-
controller
module disk
array
No on path to
failed controller
module;
Yes on alternate
path through
second
controller
module
Ownership of the failed controller module’s LUNs can transfer
automatically to the remaining operational controller module if
primary and alternate paths have been configured in LVM. If so,
LVM switches automatically and transparently to the alternate
path. The system administrator or service provider hot-swaps the
failed controller module.
Fan module
Yes
Applications continue to run. The system administrator or service
provider hot-swaps the fan module.
Power
supply
modules
Yes
Applications continue to run when one power supply module fails.
The system administrator or service provider hot-swaps the failed
power supply module.
HP Fibre
Channel-AL
Hub
No
No I/O operations are possible between the host and any disk
arrays because all I/O traffic is routed through the HP Fibre
Channel-AL Hub. The authorized service provider replaces the
failed HP Fibre Channel-AL Hub and the system administrator
restarts the operating system and applications.
Содержание Surestore Disk Array 12h - And FC60
Страница 16: ...16 ...
Страница 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Страница 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Страница 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Страница 68: ...68 Capacity Management Features ...
Страница 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Страница 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Страница 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Страница 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Страница 134: ...134 Topologies for Windows NT and Windows 2000 Figure 45 Four Host Single Hub Single Disk Array Non HA Topology ...
Страница 136: ...136 Topologies for Windows NT and Windows 2000 Figure 47 Four Host Single Switch Dual Disk Array Non HA Topology ...
Страница 138: ...138 Topologies for Windows NT and Windows 2000 Figure 48 Direct Connect Single Host Single Disk Array HA Topology ...
Страница 140: ...140 Topologies for Windows NT and Windows 2000 Figure 50 Four Host Dual Hub Dual Disk Array HA Topology ...
Страница 142: ...142 Topologies for Windows NT and Windows 2000 ...
Страница 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Страница 159: ...Installing the Disk Array FC60 159 Installation Figure 55 Enclosure EIA Positions for Legacy Cabinets ...
Страница 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Страница 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Страница 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Страница 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Страница 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Страница 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Страница 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Страница 358: ...358 Support Tools Manager ...
Страница 401: ...Controller Enclosure Modules 401 Removal and Replacement Figure 101 BBU Removal and Replacement ...
Страница 440: ...440 FCC Statements USA Only ...
Страница 466: ...466 Index ...