292
Managing the Disk Array Using Array Manager 60
Identifying Disks
Binding a LUN requires the use of unassigned disks. If you are not sure which disks are
unassigned, you can determine which disks are available.
To identify unassigned disks, type
amdsp -d <ArrayID>
The status of all disks in the array will be returned. The information includes the disk group
the disk is a member of. Disks in the Unassigned disk group can be used for binding a LUN.
You may want to print the information or write down the unassigned disks before you
begin binding the LUN.
Calculating LUN Capacity
Before actually binding a LUN, you may want to calculate how much capacity will be
available for a given set of configuration values. This command does not bind a LUN; it
simply returns the capacity that would be available if you had bound a LUN using the
values provided. You can alter the settings to see how LUN capacity is affected until you get
the desired results. Using this command before you bind a LUN will ensure that you
achieve the correct capacity.
To calculate the capacity of a LUN, type:
amcfg -C -d channel:ID,channel:ID... -r <RAIDlevel>
-s <stripe> <ArrayID>
•
RAIDlevel - the
RAID level used for the LUN. Valid RAID levels are 1, 0/1, and 5.
•
stripe - the size of the stripe element in Kbytes.
Command Example
The following example calculates the capacity of a RAID 5 LUN using four disks and a
stripe element size of 16 Kbytes.
amcfg -C -d 1:1,2:3,3:1,4:2 -r 5 -s 16 0000005EBD20
Содержание Surestore Disk Array 12h - And FC60
Страница 16: ...16 ...
Страница 36: ...36 Array Controller Enclosure Components Figure 9 Controller Enclosure Front View ...
Страница 41: ...Array Controller Enclosure Components 41 Product Description Figure 13 Controller Fan Module ...
Страница 44: ...44 Array Controller Enclosure Components Figure 15 Power Supply Fan Module ...
Страница 68: ...68 Capacity Management Features ...
Страница 117: ...Topologies for HP UX 117 Topology and Array Planning Figure 39 High Availability Topology ...
Страница 122: ...122 Topologies for HP UX Figure 40 High Availability Distance and Capacity Topology ...
Страница 126: ...126 Topologies for HP UX Figure 41 Campus Topology ...
Страница 130: ...130 Topologies for HP UX Figure 43 Four Hosts Connected to Cascaded Switches ...
Страница 134: ...134 Topologies for Windows NT and Windows 2000 Figure 45 Four Host Single Hub Single Disk Array Non HA Topology ...
Страница 136: ...136 Topologies for Windows NT and Windows 2000 Figure 47 Four Host Single Switch Dual Disk Array Non HA Topology ...
Страница 138: ...138 Topologies for Windows NT and Windows 2000 Figure 48 Direct Connect Single Host Single Disk Array HA Topology ...
Страница 140: ...140 Topologies for Windows NT and Windows 2000 Figure 50 Four Host Dual Hub Dual Disk Array HA Topology ...
Страница 142: ...142 Topologies for Windows NT and Windows 2000 ...
Страница 158: ...158 Installing the Disk Array FC60 Figure 54 Enclosure EIA Positions for System E Racks ...
Страница 159: ...Installing the Disk Array FC60 159 Installation Figure 55 Enclosure EIA Positions for Legacy Cabinets ...
Страница 161: ...Installing the Disk Enclosures 161 Installation Figure 56 Disk Enclosure Contents ...
Страница 172: ...172 Installing the Controller Figure 62 Controller Enclosure Package Contents ...
Страница 174: ...174 Installing the Controller Figure 63 Mounting the Controller Enclosure ...
Страница 234: ...234 Adding Disk Enclosures to Increase Capacity ...
Страница 274: ...274 Managing the Disk Array Using SAM Unassigned disks selected as hot spares ...
Страница 345: ...HP UX Diagnostic Tools 345 5 HP UX DIAGNOSTIC TOOLS Overview 346 Support Tools Manager 347 ...
Страница 350: ...350 Support Tools Manager Figure 90 mstm Interface Main Window ...
Страница 358: ...358 Support Tools Manager ...
Страница 401: ...Controller Enclosure Modules 401 Removal and Replacement Figure 101 BBU Removal and Replacement ...
Страница 440: ...440 FCC Statements USA Only ...
Страница 466: ...466 Index ...