112
No.
Item
Range Description
5
MCU Output [CH1/Master]
0~31
Set the volume of audio channel 1 of MCU.
7
MCU Output [CH2]
0~31
Set the volume of audio channel 2 of MCU.
8
MCU Output [Monitor]
0~31
Set the volume of monitor output of MCU.
9
MCU Amp [CH1]
0~31
Set the volume of power amplifiers which are
connected to CH1 of MCU.
10
MCU Amp [CH2]
0~31
Set the volume of power amplifiers which are
connected to CH2 of MCU.
11
MIC Input
0~31
Set the volume of the audio signal from remote call
stations.
12
Z8-x Amp [CH1]
0~31
Set the volume of power amplifiers which are
connected to CH1 of RK-ZONE8 with the address x.
13
Z8-x Amp [CH2]
0~31
Set the volume of power amplifiers which are
connected to CH2 of RK-ZONE8 with the address x.
In the volume setting interface, rotate the knob to move the cursor and press it to enter the setting
interface as shown below. Rotating the knob can adjust the value.
Select
Return
and press the knob to exit the volume setting interface and return to the previous menu.
Schedule Item
Users can view, enable, or disable the timing task via Schedule Item. The setting is only valid for the
current day. All the timing tasks will be displayed in Schedule Item. The icon
beside the timing
task means it is enabled and pressing the knob again will disable it. Users can view more tasks by
rotating the knob.
Users can select Return and press the knob to go back to the
“System Setting” page.