15
No.
Button/Indicator
Light
Description
1
Device status
indicator lights
To indicate the status of power supply, main power fault, backup
power fault and protection.
POWER indicates the power supply status; the light is green
when the DA is powered on.
MAINS indicate the main power supply fault status. If main
power supply fails, the light turns yellow.
BACKUP indicates the backup power supply fault status. If
the backup power supply fails, the light turns yellow.
PROTECTION indicates the DA protection status. If the
output is switched off due to overload, short-circuit or
overheating, the light turns yellow.
2
VU meter
To indicate the DA input signal level. The top red indicator shows the
input signal is too high.
Rear Panel
No.
Buttons/Indicators
Description
1
Cooling fan
2
Audio input & fault
interface
FAULT indicates when the DA experiences a fault, it is disabled
and sends a fault output via dry contact.
LINE IN indicates the balanced input interface, for the input of
an external audio source.
BOOSTER INPUT indicates the 100 V audio input, capable to
connect to other DA output.
3
PA interface
To connect to the RK-MCU or zone expanders to receive audio
and control signal.
4
Work mode setting
switch
To set the DA function, such as main power fault detection,
backup power fault detection and power saving function.
5
DA output interface
To output the amplified 70V/100V audio signal.
6
Main power & fuse
To connect to the AC power supply. A fuse must be installed in
the socket for over current protection.
7
Power switch
To turn on or turn off AC power.
8
Backup power input
To connect to 24V DC backup power supply.
9
Grounding screw
To connect to grounding wire.