Installation and Set-Up Guide    

 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

This control complies with EN50131-1

 

 

Содержание Ademco Vista-12D

Страница 1: ...K10022V1 4 05 Rev A A AD DE EM MC CO O V Vi is st ta a 1 12 2D D Installation and Set Up Guide This control complies with EN50131 1 ...

Страница 2: ...Installation and Setup Guide ii ...

Страница 3: ... 2 11 Installing the Transmitters 2 12 Installing a Keyswitch 2 12 Connecting Relay Modules 2 14 Powerline Carrier Devices 2 16 On Board Triggers 2 17 Phone Line Connections 2 18 Alternative Communications Media ACM Connections 2 18 Audio Alarm Verification Connections AAV Listen In 2 18 Programming Overview 3 1 About Programming 3 1 Zones and Partitions 3 2 Keypads 3 2 Wireless Receiver Transmitt...

Страница 4: ...57 Menu Mode 5 20 Programming Function Keys 5 20 About Descriptor Programming 82 Menu Mode 5 22 Configurable Zone Type Programming 83 Menu Mode 5 24 Programming Installer and User Schedules 5 26 System Communication and Operation 6 1 Panel Communication with Central Station 6 1 Report Code Formats 6 1 Robofon 8 Format 6 3 ADEMCO Contact ID 6 4 Security Codes 6 6 Keypad Functions 6 7 Panic Keys 6 9...

Страница 5: ...ter Compass downloading software and an ADEMCO CIA CIA EU modem Functions Single button arming feature Can use dedicated keys to arm the system AWAY or STAY Up to 8 Schedules to control output devices to determine when users have access and or to auto arm disarm or allow disarm the system Up to 2 Keypad macros which can be activated by wired wireless keypads Paging feature allows certain system co...

Страница 6: ...e expander module Supports 5881 5882EU 5882EUH 5883 series receiver and 5800 5800EU 5800H 5800AP series transmitters Outputs up to 4 relays two on board triggers and or Powerline Carrier Devices X 10 type Use any combination of 4204 4229 6164 relays and or Powerline Carrier Devices Output functions up to 12 Alarm power output provides a 12VDC 2 AMP output that can drive compatible sounders with a ...

Страница 7: ...ay Modules section 6164 Keypads must be set for two addresses a keypad address and a zone expander address if using the keypad s expansion zones This control will not power up unless AC mains is connected will not power up on battery alone However once the system is powered up it will operate on battery power in the event of AC mains loss Relays have two programming menu modes Use 79 Menu mode to ...

Страница 8: ...Installation and Setup Guide 1 4 ...

Страница 9: ...ow 5 Swing base of circuit board onto the raised cabinet tab and standoff 6 Secure the sides of the PC board to the enclosure using the 2 screws provided Notes Before installing the cabinet s contents remove the metal cabinet knockouts required for wiring entry Do not remove the knockouts after the circuit board has been installed Cabinet and Lock 1 Mount the control cabinet to a sturdy wall in a ...

Страница 10: ...Installation and Setup Guide 2 2 V12D 001 V0 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 21 22 23 25 Figure 2 Mounting the PC Board ...

Страница 11: ...WIRE V TO KEYPAD YEL DATA WIRE TO KEYPAD GRN DATA WIRE TO KEYPAD BLK GROUND WIRE V TO KEYPAD RED POWER WIRE V TO KEYPAD GRN DATA WIRE TO KEYPAD YEL DATA WIRE pwr_sup_conn 008 V0 Figure 3 Using a Supplementary Power Supply Notes Typical Fixed Word Display 6128RF 6148 6150 6150RF 6150V Typical Alpha Display 6160 6160V 6160RF 6164 The system supports up to 8 keypads which can be assigned to partition...

Страница 12: ...er connections to alarm output terminals 3 and 4 For supervised output continue with steps 2 and 3 2 Cut the red Siren Supervision Jumper located above terminals 2 and 3 on the control board 3 Connect a 2k ohm resistor across the terminals of the last sounder _ _ 2 EXTERNAL ALARM SOUNDER TERMINALS ON CONTROL BOARD ALARM OUTPUT TERMINALS V48sounder 001 V0 3 4 CUT RED JUMPER ON CONTROL BOARD TO ENAB...

Страница 13: ...uard against blowing the transformer fuse the fuse is non replaceable Wiring to the AC transformer must not exceed 76m using 1 2mm O D wire The voltage reading between terminals 1 and 2 of the control must not fall below 16 5VAC or an AC LOSS message will be displayed Do not connect to AC mains power while making any wiring connections to the control As a safety precaution always power down the co...

Страница 14: ...ly expected levels of lightning and electrical discharge and does not normally require an earth ground If an earth ground is desired for additional protection in areas of severe electrical activity terminal 25 on the control board or the cabinet may be used as the ground connection point The examples of good earth grounds listed at the left are available at some installations AUXILIARY DEVICE CURR...

Страница 15: ... or emergency zones only Do not use double balanced zones as fire zones Zone Doubling Connections as shown resistors provided 2k 2k 2k ZONE 3 2k 2k 2k ZONE 4 12 13 14 zone 002 V0 TAMPER CONTACTS TAMPER CONTACTS 10 11 6 2k ZONE 10 3k ZONE 2 zone 004 V0 Double Balanced Zones Zone Doubling Figure 5 Configuring Zones Notes EOLR If the EOLR is not at the end of the loop the zone is not properly supervi...

Страница 16: ... again the control will disregard the first trigger and no alarm signal will occur This feature eliminates false alarms from smoke detectors due to electrical or physical transients The zone 1 alarm current supports only one smoke detector in the alarmed state Do not use 4 wire smoke detectors on zone 1 Maximum current for trigger 17 output for 4 wire smoke detectors is 100mA Figure 6 4 Wire Smoke...

Страница 17: ... zones have normal response time 400 500 msec except zone connected to each module s loop A which can be set for fast response 10 15 msec Do not use fast response in Western Europe fast response is not permitted by EN50131 1 prEN50131 3 BRN GRN BLK GROUND RED 12VDC YEL 4 3 2 1 ZONES A B C D F G H DIP SWITCH FOR SETTING ADDRESS AND ZONE A RESPONSE TAMPER JUMPER POSITION 4229 IN CABINET NOT TAMPER 4...

Страница 18: ...6164 keypad supports up to 4 wired expansion EOLR or double balanced zones and one relay output Use 2000 ohm end of line resistors at the end of loops connected to the 6164 keypads Enter 6164 keypad program mode by pressing and holding down both the 1 and 3 keys within 60 seconds of power up Enable the keypad addresses using data fields 191 196 as required Program keypad zones using 56 Menu mode K...

Страница 19: ...ntrally located area for best reception Do not locate the receiver or transmitters on or near metal objects This will decrease range and or block transmissions Do not locate the RF receiver in an area of high RF interference indicated by frequent or prolonged lighting of the LED in the receiver random flicker is OK Do not locate RF receiver closer than 3m from any keypads to avoid interference fro...

Страница 20: ...U 5802MN 5802MN2 5804EU and 5804 Button Transmitters have replaceable batteries Do not install batteries in wireless transmitters until you are ready to enroll during system programming After enrolling batteries need not be removed Installing a Keyswitch 1 Connect the 4146 keyswitch s normally open momentary switch to a zone s terminals zones 2 8 Remove the 2000 ohm EOL resistor if connected acros...

Страница 21: ... N C ARMED RED YELLOW WHITE EOLR use appropriate value 11 10 TYPICAL ZONE ON CONTROL BOARD BROWN BLUE BROWN BLUE 820 ohms 820 ohms 00 trigcon 004 V2 1 3 4 5 6 7 8 4 WIRE CABLE 8 PIN TRIGGER CONNECTOR KEY 12 AUX OUTPUT 17 OUTPUT 18 RED YELLOW GREEN RED BLACK Figure 9 Keyswitch Wiring Connections ...

Страница 22: ... from the control s terminals or if the module cover is removed and the tamper jumper is installed Alpha CHECK xx Wire Expansion FAULT xx Wire Expansion TAMPER xx Wire Expansion ALARM xx Wire Expansion Fixed Glass lxx or 91 if field 199 set for 2 digit display where xx is the module s address If communication tamper failure occurs on a device with zones wired to it all zones on the device will be ...

Страница 23: ...Mounting and Wiring the Control 2 15 Figure 10 4204 Connections to Control 4229 Module and 6164 Keypad is shown in the Expansion Zones sections on page 2 9 ...

Страница 24: ...dulator It supplies signals from the control panel through the premises AC mains wiring to the Powerline Carrier devices which are plugged into AC outlets You can then make devices that are plugged into Powerline Carrier devices perform various functions in response to commands you enter at the security system keypads 1 2 3 4 SA4120XM 1 CABLE PART OF 4120TR XM10E POWERLINE INTERFACE MODULATOR YEL ...

Страница 25: ...ure 12 On Board Trigger Connector with 4 Wire Cable for Trigger Use Only Notes There are two on board triggers that can be used to activate output devices These outputs are normally high and go low upon programmed condition The outputs can be programmed for inverted operation normally low go high using 79 Menu mode Program these triggers using 80 81 Menu modes as you would for any other relay outp...

Страница 26: ...diagram below Connections use one of the on board triggers Suggested AAV Module ADEMCO UVS shown or Eagle 1250 Notes Set field 91 for AAV and program the appropriate output output 17 or 18 using 80 Menu mode select zone type 60 For voice session monitoring connect an EOLR zone to UVCM module terminals 6 7 and program the zone as zone type 81 56 Menu mode E g Using output 18 for the trigger program...

Страница 27: ...iptors and serial numbers for RF transmitters 57 Function Key Programming Program each of the four alphabet function keys to perform one of several system operations 58 Zone Programming Assign zone attributes similar to 56 mode but provides a faster Expert Mode programming procedure and is intended for those more experienced in programming controls of this type 79 Output Device Mapping Assign devi...

Страница 28: ...partition The following describes the functioning of the common area partition if used The common area sounds and reports alarms only when both the other partitions are armed If only one partition is armed the system ignores faults in the common area Either partition may arm its system if the common area is faulted but once armed the other partition will not be able to arm unless the common area z...

Страница 29: ...ng DIP switch equipped wireless keypads for each partition 25 Arming Prevention Override 67 Transmitter Low Battery Report Code 75 Transmitter Low Battery Restore Report Code 173 RF Reporting Options 178 RF Supervision RF Jam Options Use 56 Menu mode to program wireless zones 9 24 and wireless button zones 49 64 Transmitters Use 56 or 58 Zone Programming Menu modes to program zone information and ...

Страница 30: ... the desired zone type using 56 Zone Programming mode then use 57 Function Key menu mode to assign the desired key If using a function key to activate a relay action 57 Menu mode key function 07 use 79 Menu mode to map the output and use 80 Menu mode to define the output s action select system operation type 66 If using a function key for a user macro use 57 menu mode to activate the desired key t...

Страница 31: ...ollower Assign to a zone covering an area such as a foyer lobby or hallway through which one must pass upon entry to and from the keypad Provides a delayed alarm using the programmed entry 1 time if the entry exit zone is faulted first Otherwise this zone type gives an instant alarm Active when the panel is armed in the Away mode Bypassed automatically when the panel is armed in the Stay or Instan...

Страница 32: ... a CHECK message indicating the appropriate zone but keypad beeping does not occur Upon restoral of the zone the message RESTORE 24 Hr Non Burg XXX will be sent to the Central Station The CHECK message will automatically disappear from the keypad dynamically when the zone restores a user code off sequence is not needed to reset the zone Faults of this zone type are independent of the system and ca...

Страница 33: ...larm sounding and dialer reporting stops except for fire alarms which immediately terminate the voice session and cause a fire report to be sent When the zone is restored session ended sounding resumes if bell timeout has not expired and reports that were stopped are sent Type 82 Blockschloss Used with special blockschloss lock and key System arms 5 seconds after the key is fully turned arms MAXIM...

Страница 34: ...abled the Installer code remains active until any other user enters their code To enable the Installer code master code 65 Go to a Data Field Press Field Number for example 21 A display of EE or Entry Error means you have entered a nonexistent field Simply re enter plus a valid field number Entering Data When the desired field number appears simply enter the digits required The keypad beeps three ...

Страница 35: ... of power up Table of Device Addresses This Device Uses Address Reports as Enabled By RF Receiver 00 100 56 zone programming input device type entry Alternative Communication Media ACM 03 103 automatic if output to ACM field 29 enabled Telecommand Voice Module 17 23 117 123 same as keypad enables see below Zone Expanders 4219 4229 zones 17 24 08 108 56 zone programming input device type entry then...

Страница 36: ...Installation and Setup Guide 3 10 ...

Страница 37: ...nstaller Code is used to assign the 4 digit Master Security Code See Master Code in the System Operation section for procedure 21 Quick Arm Enable 0 do not allow quick arm 1 allow quick arm If enabled a user code is not needed to arm the system Instead users can press the followed by an arming key to arm the system However the user code is always needed to disarm the system 22 RF Options Entry 1 J...

Страница 38: ...tery enter 5 1 4 NOTE If tamper option 1 or 2 is selected field 175 digit 2 must be 0 Must be 0 for prEN50131 3 compliance 26 Chime By Zone 65 Prog Mode Entry 1 Chime by Zone 0 no zone list chimes on fault of any entry exit or perimeter zone when chime mode on 1 use zone list chimes on fault of specific zones programmed in zone list 3 when Chime mode on Entry 2 65 Program Mode for Installer Code A...

Страница 39: ...0 No No No 1 Yes No No 2 No Yes No 3 Yes Yes No 4 No No Yes 5 Yes No Yes 6 No Yes Yes 7 Yes Yes Yes 32 Fire Alarm Sounder Timeout 0 yes fire sounder timeout after time programmed in field 33 1 no fire sounder timeout continue sounding until manually turned off Select whether fire alarm sounding expires after sounder timeout or remains until manually turned off 33 Siren Timeout 0 No timeout 4 4 min...

Страница 40: ...ng trigger activation duration arm 2 dings of selected duration with 1 second off between disarm 1 ding of selected duration Ding occurs upon reception of the wireless arming command NOTE If using an option that activates trigger 2 trigger 2 must be dedicated to only this function do not assign any other functions to trigger 2 39 Power Up In Previous State 0 always power up in a disarmed state 1 a...

Страница 41: ...d press 45 46 Part 2 Secondary Subs Acct No Enter digits 0 9 11 for B 12 for C 13 for D 14 for E 15 for F Enter up to 10 digits depending on the report format selected in field 48 To clear entries from field press 46 47 Phone System Dialer Attempts Phone System Select If Central Station Receiver is not on satellite link 0 Decadic Pulse Dial 1 Multifrequency Tone Dial If Central Station Receiver is...

Страница 42: ...mes a 15 second delay e g 1 15 seconds 2 30 seconds etc Intended for use with ECP Contact ID Output reporting via ACM This field lets you select the time the panel should wait for acknowledgment from the first reporting destination see 55 before it attempts to send a message to the second destination Delays can be selected from 0 to 225 seconds in 15 second increments This delay is per message If ...

Страница 43: ...TITLE and DATA ENTRIES EXPLANATION 59 Exit Error Report Code 0 no report 1 F report code see description above After arming the system zones remaining open after exit delay expires cause an alarm sound at the keypad and external sounder keypad also displays EXIT ALARM and entry delay begins Disarming before the end of the entry delay stops the alarm sounding and no message is sent to the central s...

Страница 44: ...9 Alarm Restores Send restore code if fault cleared 0 at siren timeout if restored or at disarm whether restored or not 1 dynamically as the fault clears 2 only after a disarm Alarm restore message will be sent upon condition selected 70 Alarm Restore Report Code 0 disable 1 F see description above 59 Sent when an alarm zone is restored to its non faulted condition or at the times selected in fiel...

Страница 45: ...ultiple partitions e g for partitions 1 and 2 enter 3 If enabled the system will automatically change AWAY or MAXIMUM modes to STAY and INSTANT modes respectively if the entry exit door is not opened and closed within the exit delay time after a user arms in AWAY mode from a wired keypad non RF device An Opening report followed by an Armed Stay report is sent to the Central Station If the door is ...

Страница 46: ...e between 30 and 60 minutes after fail 1 6 10 to 60 minutes in 10 minute increments 1 10 min 2 20 min 3 30 min 4 40 min 5 50 min 6 60 min Cancel Verify Display When enabled 1 yes this feature causes a CANCELED ALARM display on the LCD keypad under the following conditions After the kissoff of the cancel message to the Central Station indicating a successful transmission When an alarm is successful...

Страница 47: ...eport Code 0 disable 1 F see description above 59 If an Event Logging selection is made in field 90 a message can be sent to the central station receiver when the log is 80 full If the log becomes full new messages overwrite the oldest messages in the log 90 Event Log Enables 0 no event logging 1 log Alarm Alarm Restore 2 log Trouble Trouble Restore 4 log Bypass Bypass Restore 8 log Open Close x l...

Страница 48: ...pad display only when phone line is faulted 1 keypad display plus keypad trouble sound when line is faulted Each partition turns off its own trouble sound No automatic timeout 2 Same as 1 plus programmed output device STARTS If any partition is armed external sounder activates External sounder will be turned off by normal siren timeout or by security code plus OFF from any partition it does not ha...

Страница 49: ...t this field to 5 This allows access via the phone module if the answer fax machine is turned off yes no yes 1 14 not 0 yes yes yes 15 bypasses answer fax machine no no no 0 no yes no 0 no no yes 1 14 no yes yes 15 NOTE If 15 is entered to bypass an answering machine and a TeleCommand Phone Module is included in the system you should note the following When calling in from an off premises phone th...

Страница 50: ...mit Some paging systems require pause s before the prefix The format for the 7 digit system status code is defined as follows Pager Format XXX YYYY where XXX 3 digit event code 911 Alarm 811 Trouble 101 Opening disarm 102 Closing arm YYYY 4 digit user or zone number depending on type of event The first digit indicates partition followed by 0 then the 2 digit user or zone number Example 1 Pager dis...

Страница 51: ... in the system Miscellaneous System Fields FIELD TITLE and DATA ENTRIES EXPLANATION 173 RF REPORTING OPTIONS 0 none 1 RF Tamper reports during disarm 2 RF keyfobs send low battery 3 RF Tamper reports during disarm and RF keyfobs send low battery Select desired option 175 Tamper Options Entry 1 0 standard tamper detection 1 detect tamper from bypassed zones 2 detect tamper when in Test mode 3 detec...

Страница 52: ... armed 3 Report RF Jam and RF supervision failure as tamper alarm when armed Select desired option See field 22 for related options Entry 0 RF jam conditions report as Trouble zone 90 Contact ID code 344 RF Rcvr Jam Detect plus a zone trouble report for each RF zone in the system CID code 383 Trouble Sensor Tamper when the system is armed or disarmed Keypads display Tamper zz zz zones and Tamper 9...

Страница 53: ... no no 1 50Hz clock backup no no 2 60Hz clock no no 3 50Hz clock no no 4 60Hz clock backup yes no 5 50Hz clock backup yes no 6 60Hz clock yes no 7 50Hz clock yes no 8 60Hz clock backup no yes 9 50Hz clock backup no yes 10 60Hz clock no yes 11 50Hz clock no yes 12 60Hz clock backup yes yes 13 50Hz clock backup yes yes 14 60Hz clock yes yes 15 50Hz clock yes yes 182 Summer Time Switchover Day 0 swit...

Страница 54: ... must be dedicated to only this function do not assign any other functions to trigger 1 188 Keypad Sabotage Options Entry 1 Keypad Lockout 0 disable 1 enable 15 minute lockout Entry 2 Keypad Supervision and Tamper Fault Detection 0 no 1 yes Entry 1 If selected will lockout the keypad for 15 minutes if 30 keystroke entries 6 attempts of code command are made without a valid user code being detected...

Страница 55: ...is located Entry 2 Enter the desired sound option for this keypad NOTE Address 16 is reserved for keypad 1 which is factory set to partition 1 with all sounds enabled 191 Keypad 3 Device Address 18 See field 190 for entries Keypad 3 See field 190 for explanation 192 Keypad 4 Device Address 19 See field 190 for entries Keypad 4 See field 190 for explanation 193 Keypad 5 Device Address 20 See field ...

Страница 56: ...98 Display Partition Number 0 no 1 yes If selected the partition number is displayed in the upper left corner of the display This is useful when using the GOTO partition function 199 ECP Device Fail Display 0 3 digit display 1 device address 1 2 digit fixed display as 91 Select 0 if using Alpha keypads and or 3 digit Fixed Word Display keypads 6148 6150 6160 6164 ECP faults for keypads and or othe...

Страница 57: ...programming control panels of this type NOTE Alpha display prompts are shown in a double line box 56 Zone Programming Procedure Zone Programming involves 1 Entering the zone number to be programmed 2 Making appropriate entries at the prompts 3 Confirming the serial number of wireless transmitter zones Start Zone Programming mode by pressing 56 while in Data Programming mode The following prompts a...

Страница 58: ...or zone 91 to enable addressable device reporting Enter a report code for zone 92 to enable duress reporting 95 96 99 are emergency panic key zones Zn ZT P RC In L 17 00 1 10 RF 1 OR Zn ZT P RC In AD 17 00 1 10 AW 07 OR Zn ZT P RC HW RT 17 00 1 10 EL 1 Summary Screen to continue A summary display appears IN L appears for wireless zones and indicates input type and loop IN AD appears for wired expa...

Страница 59: ...ntered 3 Common Partition 17 Report Code 1st 01 2nd 00 10 Report Code RC First Digit 01 09 10 for 0 11 for B 12 for C 13 for D 14 for E 15 for F 00 to disable Second Digit same as above to continue Enter the report code for this zone which consists of 2 hexadecimal digits each in turn consisting of 2 numerical digits For example for a report code of 10 enter 01 and 00 For Contact ID entering any n...

Страница 60: ...eceiver s range UR Sends all the signals that the RF type Unsupervised RF does but the control does not supervise the check in signals The transmitter may therefore be carried off premises BR Unsupervised Sends only fault signals It does not send a Button RF low battery signal until it is activated The transmitter may be carried off premises RM Sends periodic check in signals as well as fault Supe...

Страница 61: ... programming a transmitter with several input loops 17 INPUT S N L A022 4064 Loop Number Change to continue NOTE If the C key is used to copy the previously enrolled serial number the cursor will move to the Loop column L with the previous serial number displayed and display a highlighted question mark for the loop number Enter the loop number and press The system will now check for a duplicate se...

Страница 62: ...i e summary display does not appear press the key twice and then enter or transmit the correct serial number Press to continue Zn ZT RC In L 17 03 10 RF 1s Summary Screen to continue If the serial number transmitted matches the serial number entered the keypad will beep 3 times and a summary display will appear showing that zone s programming Note that an s indicates that a transmitter s serial nu...

Страница 63: ...nt to that device 58 Expert Programming Mode Procedures This method is designed for use by installers with previous experience in programming ADEMCO control panels This mode is also used to program wireless keys using pre defined templates Start Expert Programming mode by pressing 58 while in Data Programming mode The following prompts are displayed PROMPT VALID ENTRIES EXPLANATION SET TO CONFIRM ...

Страница 64: ... Zone Type prompt P partition 1 2 3 common RC 0 9 cannot enter hex report codes use 56 mode to enter hex codes IN input type L loop number to continue A summary screen with the selected zone s current programming appears Begin programming zone information as follows Enter Zone Type ZT Partition P Report Code RC and Input Device Type IN sequentially but not the Loop No L NOTE Hexadecimal report cod...

Страница 65: ... s as shown If 0 was entered in error simply re enter the loop number and the serial number will return to the display 10 XMIT TO CONFIRM PRESS TO SKIP Confirm to continue The prompt to confirm appears This prompt will only appear if the first prompt after entering 58 was answered Yes To confirm activate the loop input or button that corresponds to this zone The system checks for a duplicate If a ...

Страница 66: ...58 Menu mode to enter and duplicate 5804 and or 5804BD wireless keys the following screens appear PROMPT VALID ENTRIES EXPLANATION TEMPLATE 1 6 1 Template Number 1 3 5804 templates 4 6 5804BD templates to continue 1 Enter Template number 1 6 from next page See the defaults provided for each template in the chart that follows these procedures 2 Select from templates Press to display template 1 show...

Страница 67: ... INPUT S N L AXXX XXXX Serial Number to continue 10 Manually enter the serial number printed on the label for the wireless key or press and release the button to transmit its serial number 11 Press to accept the serial number The system will check for duplicate 12 If necessary press the key to back up without saving and re enter the serial number Use the A key to move forward within the screen and...

Страница 68: ...ONE of the serial number labels from the device and affix it in the appropriate column on the ENROLLED TRANSMITTERS worksheet of the Programming Form then enter the other information zone number zone type loop number etc relevant to that device Wireless Key Predefined Default Templates 5804 Wireless Key Transmitter 5804BD 2 Way Wireless Key Transmitter 5804 5804BD Template 1 Loop Function Zone Typ...

Страница 69: ...ge an entry Press to go forward again Output Device programming involves 1 Use 79 Menu Mode to assign module and output numbers and map them to device addresses NOTE You must map output devices using 79 Menu Mode before you can use 80 Menu Mode 2 Use 80 Menu Mode to create output definitions which control the output devices 79 Menu Mode Output Device Mapping Use this menu to assign Relay Module de...

Страница 70: ...tive power terminal of the smoke detector selecting 1 at this prompt and setting as zone type 54 fire zone reset in 80 Menu mode After entry display returns to Output Number prompt Use 80 Menu mode to program the function of the trigger XX OUTPUT TYPE DELETE 0 Output Type 0 delete 1 relay on 4204 4229 module or 6164 keypad 2 Powerline Carrier device to continue Select whether this is a relay or a ...

Страница 71: ...s on a zone a zone list or a zone type Event Event that triggers the output action Can be an event occurring on a specific zone number or a zone list or a specific zone type Partition If the output is activated by zone type this defines the partition in which the programmed event is to cause the device action Output Action Defines the action of the relay X 10 device when the defined event occurs C...

Страница 72: ...output function number to be defined or 00 to exit 01 A E P Trig 00 0 0 ZL 1 Summary Screen to continue This screen displays a summary of the current output programming for this example Zone List has been selected this is the default screen A Output Action E Triggering event P Partition Trig Trigger type NOTE A question mark in the summary screen indicates that the device number shown has not been...

Страница 73: ...nt Exit 1 06 24 Hr Silent 16 Fire w verification 02 Ent Exit 2 07 24 Hr Audible 23 No Alarm Response 03 Perimeter 08 24 Hr Aux 24 Silent Burglary 04 Interior Follower 09 Fire 77 Keyswitch 10 Interior w Delay 81 AAV Monitor Zone 12 Monitor Zone 82 Blockschloss 14 Gas 90 93 Configurable CHOICES FOR SYSTEM OPERATION 20 Arming Stay 36 At Siren Timeout 54 Fire Zone Reset 21 Arming Away 38 Chime 58 Dure...

Страница 74: ...device output number programmed in 79 Menu Mode you want associated with this output Press to continue 02 A E P TRIG R02 1 1 3 ZL 1 Summary Screen A summary screen appears showing the programmed settings Press to continue About Zone Lists 81 Menu Mode Zone lists let you group individual zones for use with certain system actions The following table shows the available zone lists and their purposes ...

Страница 75: ...he Zone List No prompt To save the zone list enter 0 01 Delete Zone 0 No 1 Yes 0 Deleting a Zone 0 don t delete zones 1 go to next prompt to delete zones to continue To save the entire zone list enter 0 and the system returns to the Zone List No prompt To delete a zone or zones in a zone list enter 1 to continue 01 Zn to Delete 00 Quit 00 Delete the Zone 01 06 9 24 49 64 zones to be deleted from l...

Страница 76: ... and partition 2 Selecting the desired function for that key Start Function Key Programming mode by pressing 57 while in Data Programming mode The following prompts are displayed PROMPT VALID ENTRIES EXPLANATION Press Key to Pgm 0 Quit 0 Function Key Press the desired function key A D to continue Press the desired function key A D you want to program NOTE A key programmed as a function key is no l...

Страница 77: ...l be as follows If A selected Zone 95 emergency key same as 1 pair If B selected Zone 99 emergency key same as pair If C selected Zone 96 emergency key same as 3 pair If D selected Single button paging 01 Single button paging sends a 999 9999 message to pager 02 Display time 03 Arm AWAY reports as User 00 if closing reports are enabled 04 Arm STAY reports as User 00 if closing reports are enabled ...

Страница 78: ...e by pressing 82 while in Data Programming mode PROMPT VALID ENTRIES EXPLANATION Program Alpha 0 No 1 Yes 00 Program Alpha 0 no 1 yes to continue The Program Alpha prompt will appear Press 1 to program zone descriptors or partition descriptors Press 0 to exit Sel Zone Des 0 Part Rmndr 1 Select Descriptor Type Zone Descriptor or Partition Descriptor Words 0 create zone descriptors see Zone No promp...

Страница 79: ...done press the 8 key to save the descriptor and return to the Zone No prompt 4 Enter the zone number for the next descriptor press and repeat steps 1 3 To change a descriptor simply overwrite it To exit enter zone number 00 CHARACTER ASCII CHART 032 space 033 034 035 036 037 038 039 040 041 042 043 044 045 046 047 048 0 049 1 050 2 051 3 052 4 053 5 054 6 055 7 056 8 057 9 058 059 060 061 062 063 ...

Страница 80: ...Proc prompt 90 Bypass Option 0 Bypass Option 0 zone type cannot be bypassed 1 auto bypassed when armed in stay mode to continue Enter the desired bypass option 90 Resp to Short Armed 0 DArmd 0 Response to Shorts 0 none 2 trouble 1 Alarm 3 fault to continue Select the type of response when zones assigned to this zone type are shorted when the system is armed NOTES 1 For double balanced zones this e...

Страница 81: ... Select type of sounding upon alarm conditions on zones assigned to this zone type 90 Dial Delay 0 No 1 Yes Dial Delay 0 no 1 yes to continue If selected faults on zones assigned to this zone type will delay reporting for whatever length of time that is selected in dial delay 50 90 Disp Option 1 Display Options 0 no display 1 display only 2 chime only 3 chime disp to continue Select whether faults...

Страница 82: ...tay Arming 05 Forced Away Arming 06 Auto Disarm 07 Display Reminder 08 Disarm Time Window 11 Periodic Test Report 12 Up and About to continue Enter the desired event number for event you want to occur at a specified time Events 10 12 are reserved for the installer only Child Not Home report option 03 is sent to all pagers in the user s partition message sent is 777 7777 User must be enabled for pa...

Страница 83: ...impending arming The system will beep once every 30 seconds to alert users that arming will soon occur Otherwise this prompt is skipped STOP SMTWTFS HH MMA M 0 0 1 0 0 0 0 Stop Time 01 12 00 23 hour 00 59 minute 0 AM 1 PM if applicable Days place 1 under days to continue Enter the event s stop time and days of the week to occur To select days position the cursor under the desired days using the ke...

Страница 84: ... minutes of the hour time For example if a schedule is set to start at 6 15pm it will do so the first time 6 15pm arrives but on subsequent days it will start anytime between 6 00 and 6 59 p m NOTE Do not use the random option if the start and stop times are within the same hour setting otherwise unpredictable results may occur e g the randomized stop time may occur before the start time ...

Страница 85: ... panel the panel sends its message If there is an error in the transmission the receiver does not receive a valid message the kissoff frequency is not given by the Central Station receiver The panel makes a total of eight attempts to the primary telephone number and eight attempts to the secondary telephone number if programmed to get a valid message through If the panel is not successful after it...

Страница 86: ...t qualifier new or restore 3 digit event code 2 digit partition number and 3 digit zone number user number or system status number see the following page The following table lists codes for reports sent in different formats Code for Code for Type of 3 1 4 1 3 1 4 1 Code for Report Standard Expanded 4 2 Robofon 8 Alarm SSS S A SSS S A SSSS SS AZ AAA A Z Trouble SSS S T SSS S T SSSS SS Tt TTT T t By...

Страница 87: ...umbers can be reported by assigning the A first digit as the first digit of the zone number then assigning Z as the second digit of the zone number if desired Robofon 8 Format Robofon 8 format send data in a pulsed frequency format in the following protocol First bit Last Bit Tone 0 No tone 1 Freq 1000Hz 5Hz First Byte Last Byte 50 baud 20ms bit 200ms char 11 chars message U 55h and ETX 03h Physic...

Страница 88: ...0ms and then send a new start char w The receiver can optionally send a command back to the dialer after ACK The command may be one byte with any content except w 77h ACK 06h or NAK 15h ADEMCO Contact ID ADEMCO and Robofon Contact ID Reporting takes the following format CCCC CCCCCC Q EEE GG ZZZ where CCCC CCCCCC 4 digit or 10 digit Customer subscriber ID Q 1 digit Event qualifier where E new event...

Страница 89: ...Sensor Tamper and Double Balanced Zone Tamper Code Definition 384 RF Sensor Low battery 393 Clean Me ESL smoke detectors only 401 Disarmed Armed AWAY Armed MAXIMUM 403 Scheduled Arm Disarm AWAY 406 Cancel by User 407 Remote Arm Disarm Downloading 408 Quick Arm AWAY 409 Keyswitch Arm Disarm AWAY 441 Disarmed Armed STAY INSTANT Quick Arm STAY INSTANT 442 Keyswitch Arm Disarm STAY 443 Scheduled Armed...

Страница 90: ...03 Same as Master except add delete users limited to Master assigned partition only these users can be assigned different authority default levels if desired any user can be assigned the partition master authority level 0 User 03 17 perform security functions arm disarm etc only cannot add delete users view event log set system clock or program scheduled events 1 Arm Only see user arm system only ...

Страница 91: ... those zones listed in Night Stay zone list INSTANT Yes No Yes No MAXIMUM Yes No Yes Yes Keypad Functions The following is a brief list of system commands For detailed information concerning system functions refer to the User s Manual Keypad Commands Function Description Silence alarms Pressing any key will silence the keypad sounder for 10 seconds Disarming the system will silence both keypad and...

Страница 92: ...appropriate lettered key on the keypads see Single Button Arming above Disarming Enter code OFF 1 If entry delay or an alarm is active you do not need to press OFF entering the security code alone disarms the system Bypassing Zones Enter code BYPASS 6 zone number s Can bypass while system armed disarmed Forced Quick Bypass To automatically bypass all faulted zones use the Quick Bypass method Enter...

Страница 93: ... be able to hear the message tones In the event it takes longer than two rings to answer the call it is possible the tones will have been completed and the call disconnected To help ensure that the tones are heard you should set a repeat count 1 7 repeats that will cause the tones to be repeated that number of times giving the listener a better chance of hearing them Note that only the tones are r...

Страница 94: ...ount for crystal frequency variation This adjustment is only needed if the frequency control of AC mains is not accurately maintained by the local mains electrical power provider To set and adjust the clock user code 6 3 The current setting is displayed Press to set the time A cursor appears under the first digit of the hour Enter the 2 digit hour setting then enter the 2 digit minute setting Pres...

Страница 95: ...P module problems are displayed as 91 If there are wireless sensors in the system the Check condition may also be caused by some change in the environment that prevents the receiver from receiving signals from a particular sensor TAMPER 1xx 1xx Appears when a tamper switch at the device address shown has been activated while system is disarmed TMPR_ARMD 1xx Appears when a tamper switch at the devi...

Страница 96: ...will shut down to minimize deep discharge of the battery Comm Failure FC A communication failure has occurred Open Circuit OC The keypad is not receiving signals from the control and sees an open circuit Long Rng Trbl bF Backup Alternative Communication Media communication failure Bell Failure 70 Siren supervision failure RCVR Jam 90 RF jam detected KEYPAD LOW BAT 00 BAT Wireless keypad low batter...

Страница 97: ... displayed 1 Enter Installer Code 5 TEST then press 0 at the prompt to start Walk Test mode 1 DIAL 0 WALK no special display on Fixed Word keypads The following will be displayed TEST IN PROGRESS dd displayed on Fixed Word Display Keypads A Contact ID report will also be sent code 607 2 Upon entering the system test mode the outside sounder should sound for 1 second If the backup battery is discha...

Страница 98: ...7 Any transmitter not enrolled or any zone that is not faulted will not turn off its zone number Go No Go Test Mode The Go No Go Test verifies adequate RF signal strength from the proposed transmitter location and allows you to reorient or relocate transmitters if necessary before mounting the transmitters permanently This mode is similar to the Transmitter Test mode except that the wireless recei...

Страница 99: ...ar the display and exit Automatic Standby Battery Tests 1 An automatic test is conducted every 3 minutes to ensure that a standby battery is present and properly connected If a battery is not present or is not properly connected a LOW BATTERY message is displayed and if so programmed will be reported to the central station 2 A battery capacity test is automatically conducted for 2 minutes every 4 ...

Страница 100: ...Installation and Setup Guide 7 4 ...

Страница 101: ...PUT 12VDC 600mA max FUSE Battery 3A No 90 12 3 Communication FORMAT SUPPORTED ADEMCO Express 10 characters sec DTMF multi frequency Data Tones 1400 2300Hz ACK 1400Hz KISSOFF ADEMCO Low Speed 10 pulses sec 1900Hz Data Tone 1400Hz ACK KISSOFF Radionics SESCOA 20 pulses sec 1800Hz Data Tone 2300Hz ACK KISSOFF Can report 0 9 B F Robofon 8 See description in Communication section Ademco Contact ID 10 c...

Страница 102: ...t Communicator 7845i Long Range Radio 7845C 7835C Cellular Radio in selected countries 2 Wire Smoke Detector Detector Type System Sensor Model No Photoelectric w heat sensor direct wire 2300TB Photoelectric direct wire 2400 Photoelectric w heat sensor direct wire 2400TH Photoelectric 2451 w B401B base Photoelectric w heat sensor 2451TH w B401B base Ionization direct wire 1400 Ionization 1451 w B40...

Страница 103: ...2 REED 5819 ENROLL AS RF LOOP 2 REED LOOP 3 TERMINALS LOOP 1 TERMINALS 5801 ENROLL AS UR OR RF LOOP 3 LOOP 1 LOOP 2 LOOP 4 YOU MUST ENROLL THIS BUTTON LOOP 1 LOOP 2 LOOP 4 YOU MUST ENROLL THIS BUTTON LOOP 3 LOOP 1 LOOP 2 AUX CENTER LOOP 1 PRIMARY LOOP 3 AUX RIGHT NOTE For information on any transmitter not shown refer to the instructions accompanying that transmitter for details regarding loop num...

Страница 104: ... Transmitter RF Has three unique input loop codes one for a Primary contact loop with programmable options the others for two auxiliary closed circuit contact loops 5818 Recessed Transmitter RF Reed switch magnetic contact sensor easily hidden in the frame and edge of a door or window Has a single unique input loop code 5819 Shock Processor Transmitter RF Connects to externally mounted inertia typ...

Страница 105: ...Transmitter Module Operates the system similarly to wired keypads including panics Can indicate system status via its 3 LEDs and sounder Includes 3 panic keys 5849 5852 Glassbreak Detector RF House ID must also be set 5849 requires both sound and shock of breaking glass to cause alarm to be transmitted 5852 uses intelligent acoustic processing 5890 5890PI PR Detector RF or RM Dual element passive ...

Страница 106: ...Installation and Setup Guide 8 6 ...

Страница 107: ...ess and safety hazards like smoking in bed violent explosions escaping gas improper storage of flammable materials overloaded electrical circuits children playing with matches or arson Depending on the nature of the fire and or location of the smoke detectors the detector even if it operates as anticipated may not provide sufficient warning to allow all occupants to escape in time to prevent injur...

Страница 108: ...er period shall apply Seller s obligation shall be limited to repairing or replacing at its option free of charge for materials or labor any product s which is proved not in compliance with Seller s specifications or proves defective in materials or workmanship under normal use and service Seller shall have no obligation under this Limited Warranty or otherwise if the product s is altered or impro...

Страница 109: ...2 Battery Life 2 12 Battery Tests 7 1 7 3 Bell Supervision 2 4 Bell Supervision Jumper 2 4 Bypassing Zones 6 8 Cabinet 2 1 Character ASCII Chart 5 23 Character List 5 23 Charging Voltage 8 1 Chime By Zone 4 2 Chime Mode 6 8 common zone 3 2 Communication 5 21 6 1 7 3 8 1 Contact ID Reporting 8 1 Data Field Programming Procedures 3 8 Defining Output Functions 5 15 Descriptor Programming 5 22 device ...

Страница 110: ...4 prompt to confirm 5 9 Quick Arm Enable 3 3 Relay Module Addresses 2 14 Relay Modules 1 3 2 14 Relay Programming 3 1 Remote Keypads 1 2 Report Code 3 3 4 7 4 8 4 11 5 3 5 8 6 1 Report Code Formats 6 1 Reports In Armed Period 4 12 response time 2 9 4 10 5 2 RF House ID Code 3 3 4 2 RF Interference 2 11 RF jam detection 1 2 RF Jam Option 3 3 RF Motion 5 4 RF Receiver 2 4 2 6 2 11 6 5 Ring Detection...

Страница 111: ... CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION COMPLIES WITH FCC RULES PART 68 FCC REGISTRATION NO 5GBUSA 44003 AL E RINGER EQUIVALENCE 0 1B WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM IN ADDITION THIS SYSTEM MUST BE CHECKED BY A QUALIFIED TECHNICIAN AT LEAST ONCE EVERY THREE 3 Y...

Страница 112: ...165 Eileen Way Syosset New York 11791 Copyright 2005 Honeywell International Inc www honeywell com security ÊK10022V1nŠ K10022V1 4 05 Rev A ...

Отзывы: