triggered). Check and adjust the air resource according to requirements.
Make sure the air resource at least 60psi/4.1Pa.(The lowest working air
pressure of power supply is lower than that of cutting torch).
5.Cutting torch consumables worn. Replace the consumables.
6.Components inside device have troubles. Return to the authorized
Service Center.
Warning
There is the dangerous voltage inside the device. Please do not look for the faults or repair it if
the operator who didn’t be trained by the technicians about the inspection of the electronic
component and the skill of trouble shooting.
The content of Operator Manual says common faults and trouble shooting. It is very helpful for
solving many common faults of this system. The system has to return the Service Center which
has been authorized to repair if the main complex components have some faults. You should
operate in accordance with instruction.
Instruction
Under normal condition, there will be a little air flow between protective cup and torch handle when
operate torch. Don’t tighten protective cup too much, it will cause built in components damage.
9.6.2 Plasma Power Source Daily Care and Check
The actual maintenance frequency can be adjusted by the operation environment.
Check the machine after it work for 6 hours or Daily operation.
1. To replace the cutting torch consumables if they are damaged or worn.
2. To replace the cutting torch or the cable if they were damaged.
3. Check the plasma power, twice opening power supply and voltage and flow rate.
4. Cleaning the cable of plasma power and get rid of the humidity.
5. To replace the input power cable and wire if they were damaged.
Check the machine after it work for 36 hours or every week:
1. Check if the fan is formal and air current is enough.
2. Operator must below out all dusty and filth form machine.
Notice
Please do not blow the air into power supply when to clean the machine. The metal particle will
disturb the sensitive electronic component and cause of the damage of device.
Check the machine after it work for six months or 720 hours:
1. Check the air filter, then clean and replace it by requirement.
2. Replace the wire and hose if it is the leakage and flaw.
3. Replace the switch if it is hit by arc or worn badly.