www.honeybeecnc.com
48
Dalian
Honeybee
CNC
Equipment
Co.,Ltd.
Tel:
+86
411
85865100
Fax:+86
411
85866100
air flow, RUN/
Rapid Auto
Restart/SET
switch under SET
position, the fan is
running, AC
indicator on and
air indicator off
2
.
The power supply can not operate because of the low air pressure.
Adjust the air pressure according to torch manual
3
.
Build component of the device happen to troubles. Return to repair or
let the qualified technician to mend it.
10
The cutting torch
do not generate
arc, have air flow,
AC indicator on,
air ,temperature
and DC indicator
is off.
Air pressure is lower than the minimum requirement of power supply.
The pressure will adjust up to 60
-
75psi/4.1-5.2 Pa.
11
The cutting torch
do not generate
arc, has air flow,
AC and air
indicators are on,
but the DC and
temperature
indicators are off
1
.
The air pressure is lower than the maximum requirement of cutting
torch(The maximum pressure of power supply operation is lower than that
of cutting torch operation. To adjust the air pressure.
12
The cutting torch
do not generate
arc , no air flow,
AC, air, DC
indicators are on
1. There is no trigger box inside the cutting torch. Close the power supply
and remove the protective cup, then install the torch ,cutting nozzle and
protective cup. The ON/OFF switch of power supply keep the state of ON.
2. Protective cup of the cutting torch is loose. Check the protective cup
and tighten it .
13
Cutting torch can
not start arc, AC,
temperature and
air indicator are
on, DC indicator
is off.
1
.
The air is blocked.
Check the blocked air flow and rectify the condition.
2
.
The device is too hot. Cool it down at least 5 minutes.
3
.
The input voltage is too low. Check and connect the suitable input
current.
4
.
Components inside device have troubles.The device has to return to
the authorized Service Center.
14
Cutting torch can
not triggered, AC
indicator twinkle,
air indicator is on,
temperature and
DC indicators are
off.
1
.
The system keeps on the state of protection.(Component of cutting
torch is missing or loose.) Open cutting torch trigger and keep the
ON/OFF switch on
the state of ON, then cut the main off switch and check
the components of cutting torch, Replace it if necessary. To install the
protective cup again and tighten it by hands. Please do not use any tools.
Closing the main off switch, then keep the ON/OFF switch on the state of
ON.
15
Even though the
cutting torch
Nozzle or electrode broken. Cut off power supply, uninstall protective cup,
replace nozzle or electrode, make ON/OFF switch under ON position.