www.honeybeecnc.com
24
Dalian
Honeybee
CNC
Equipment
Co.,Ltd.
Tel:
+86
411
85865100
Fax:+86
411
85866100
Pic.23 Contour
Method:
Press
【
F1
】
to run, if the torch is not on reference point (coordinate is not zero), the system will
remind:
Present reference point ---- Set the present torch point as reference point;
Reference point position--- Torch return to reference point, then start running Contour
During running contour, if the torch over steel plate range, press
【
PAUSE
】
, move torch to steel plate
edge, press
【
START
】
, system remind “ change reference point EN/ESC”? Press ENTER to confirm
the reference point change, the system will take the present position as contour and continue running
contour; press
【
ESC
】
to quit change. This operation can be repeated until find suitable place.
5.4.8 Press
【
F2
】
WENTAI
The system will prompt to run WENTAI-based machining program if this key is pressed. WENTAI is a
word machining software for CAD/CAM, widely used in cutting graphic characters in advertisement
business. This feature is required to run a WENTAI-based program.
5.4.9
【
F3
】
ROTATE(steel plate correcting feature)
Machining at rotation angle
This feature is used when the steel plate is not positioned perfectly or the steel plate needs to rotate an
angle before machining. It is allowed to use
Rotate
function along with
BEG. PT.
and
END PT.
in
Manual
mode or input the expected angle directly. After acknowledged, the system will start the machining
program at the appointed rotation angle.
Note: Counterclockwise direction is taken as positive angle.
Example
The system is able to identify and calculate the rotation angle by measuring the origin point and the end
point of an edge of steel plate(a straight line). The procedure is as follows:
Determine the datum line. Take one borderline of steel plate as baseline and move the cutting torch to
the origin point of this baseline. Press [F2] to set the beginning point of measurement.