86
Installation Instructions
Operator’s Manual
monty universal 2
iii-5
1
Pneumatic connection
PNEUMATIC INSTALLATION MUST BE PERFORMED
ONLY BY LICENSED PERSONNEL.
The machine requires an air pressure of 8 to 12 bar
(110-170 psi), as marked on the plate of the machine
and on a sticker attached to the cabinet next to the air
inlet.
Ensure tha
t the line pressure is within the limits required
by the machine.
If the air pressure is lower than the minimum required
of 8 bar (110psi) the lifting power of the turntable and
the bead breaker power may be insufficient f
or certain
tires.
Even though the machine itself has a filter, it is advisable
to fit a filter on the compressed air feed line to reduce
the quantity of air present in the line.
BEFORE CONNECTING THE MACHINE TO THE AIR
SUPPLY BE SURE THAT NOTHING IS LEFT ON
THE TURNTABLE AREA (TOOLS,ETC).
After ensuring all the above proceed as follows:
•
Connect the machine to the air supply (max.
pressure of 12 bar - 170 psi) with a rubber hose able
to withstand such pressure and having an internal
diameter of 8 mm (1/4") (
1, Fig. iii-5
).
•
To install any accessory on request follow the
instructions enclosed with it.