Hofmann Megaplan Service Manual megaline SSENCE
SSENCE 400/600
Page 30 of 52
4.5 Garage data
Garage data can be entered under setup Workshop data
Here only text can be added. This appears in the print out as table or graph.
If the text is not shown in the printout check if there are special letters included. If so select
another name.
4.6 Faulty power supply of the USB ports
In the device manager you can check if all necessary parts are available. For the aligner this
is:
If the devices are not shown correct in the device
manager, next possibility for a fault can be the
power supplies. Please check that with a
multimeter Please check the smaller power
supply to the specified voltages under load. If
nothing found, try a new power supply because
power supplies generally sometimes tend to
provide the correct values without load, but drop
in power loss in the power output.
L N
220V Input
Ground
Measuring result
between COM and V2: 11.5Volt
between COM and V1: 5Volt
If these values are too low, camera and control
board will fail because the power for this devices
is coming from this power supply.