Hofmann Megaplan Service Manual megaline SSENCE
SSENCE 400/600
Page 31 of 52
4.7 Printer Installation
SSENCE is a normal windows program and basically works with every printer that is
recognized by the system. It can be that special printer drivers from the printers manufacturer
not always work with SSENCE. If there are problems to print the form of the alignment please
try another printer driver or a compatible windows PDF printing device.
The PDF printer generates a file that can be printed by the PDF reader. In this case it is also
necessary to install a PDF reader.
If the aligner has LAN connection, also a network printing device can be used.
If there is only a white paper while printing please check the entry of the
workshop data. Aviod symbols and special letters.
4.8 Screen resolution
The standard resolution of the SSENCE aligner is 1366x768 (small HD)
If it is not possible to install this resolution , please run special software delivered with VGA
device to add customized resolution.
4.9 Hardware of aligner in device manager
Additional to the standard Windows devices the aligner places three additional devices inthe
system:
Both cameras
and the camera controll board
These devices are urgently necessary, if they are missing, the aligner can not work. If there
are unknown devices after plug in the camera, load driver of the parts from
D:\SSENCE\DRIVERS. If there are problems with installing the drivers, unplug all USB ports
from camera and control board and restart Windows. After the start plug one device after the
other and see what happens.
4.10 Camera picture is grey, blurring or complete white (F11)
The camera view can be activated with [F11]. Usually picture is shown black-white, a target in
the camera will be shown in a high contrast to the background. If the picture is grey or showing
bad contrast, try to adust values of the camera. If this is not possible or has no influence to the
picture you see, the camera chip or camera itself is damaged.
In 95% of all cases the camera chip on the backside of the camera module is broken.
If so, please go on with -- 2.3 Exchange of a camera module