Hofmann Megaplan Service Manual megaline SSENCE
SSENCE 400/600
Page 9 of 52
2.2.3 Adjustment of motor controller (400M and 600)
- Camera bar is to fast or too slow: on the backside of the controller is a table that shows all
positions of the DIP switches.
If the motor (and within the camera bar) is too fast or too slow please check the DIP switches
on the motor controller
DIP switch must be like this:
1 1 0 0 1 0 1
SW1
OFF
regular mode
SW2
ON
SW3
ON
SW4
OFF
SW5
OFF
16 Microsteps
SW6
ON
SW7
OFF
SW8
ON
amperage 3 Amp.
If the motor is very loud and rough check the adjustments of the DIP switches.