Hofmann Megaplan Service Manual megaline SSENCE
SSENCE 400/600
Page 21 of 52
3.5 USB Interface for cameras
If cameras fail, the first check is to look in the device manager of Windows system control center.
For the aligner there must be:
3.6 Bad reflection of targets (car icon in the middle)
The software shows a little car icon in the middle of the screen (bottom).
If you cross the icon with the mouse, values for target reflection are shown.
Red tire
- Connection to this tire is broken. Please
remove blocking obstacles or lift camera bar
that all targets are full visible in the camera
view [F11].
- There are more than two targets visible in the
camera view. (Reflection on the surface on the
car!)
Blue tire, number shows more than
100
- Bad Reflection, Clean targets, Eliminate
turbidity of the targets
Blue tire, number below 100
- Values OK, software can work without
problems.
Both cameras (CatchBEST) and the Camera
control board (Silabs) must be visible in the device
manager. If this is not the case, check the USB
ports on backside of the computer and on the
camera control board under the horizontal bar. Be
sure that the cables are OK. Plug and unplug the
USB ports and check what happens in the device
manager.
Check also output voltage of both (or the single
(400)) power supply. (see also 4.6)