Registering the storage system on the SVP
If you delete the registered storage system from the SVP, you can register the storage
system.
Before you begin
■
Verify the to-be-registered storage system is operating, and the IP addresses of the
SVP and the storage system are using the same subnet.
■
Upgrade the firmware for the storage system being registered.
This procedure takes approximately 10 minutes for each storage system to be registered
and approximately 200 minutes for each storage system that needs a firmware upgrade.
Note: The upgrade time can take up to 9 hours to complete when NAS
modules are installed.
Procedure
1. At the console PC connected to the physical SVP or running the SVP software, insert
the media containing the SVP firmware media.
2. On the SVP, create a new folder, and then copy all of the files from the SVP firmware
media into the new folder.
3. In the new folder, right-click the
Setup.exe
file and click Execute as
Administrator.
Registering the storage system on the SVP
Chapter 16: Deleting and registering the storage system