Rev. 6.0, 07/02, page 723 of 986
Start
Initialization
Start of reception
Read receive data from
SCRDR1 and clear RDRF flag
in SCSSR1 to 0
ORER = 0 and PER = 0?
RDRF = 1?
All data received?
Clear RE bit in SCSCR1 to 0
End of reception
Error handling
No
Yes
Yes
Yes
No
No
1
2
3
4
5
6
Figure 17.9 Sample Reception Processing Flowchart
Mode Switching Operation: When switching from receive mode to transmit mode, first confirm
that the receive operation has been completed, then start from initialization, clearing RE to 0 and
setting TE to 1. The RDRF flag or the PER and ORER flags can be used to check that the receive
operation has been completed.
When switching from transmit mode to receive mode, first confirm that the transmit operation has
been completed, then start from initialization, clearing TE to 0 and setting RE to 1. The TEND
flag can be used to check that the transmit operation has been completed.