Rev. 6.0, 07/02, page 412 of 986
master other than the SH7750 Series requesting the bus, or the bus arbiter, and returning the
bus to the SH7750 Series.
TRr2
TRr3
TRr4
TRr5
Trc
TRr1
Trc
Trc
CKIO
A25–A0
RD/
D63–D0
Figure 13.25 DRAM Self-Refresh Cycle Timing
Power-On Sequence: Regarding use of DRAM after powering on, it is requested that a wait time
(at least 100
µ
s or 200
µ
s) during which no access can be performed be provided, followed by at
least the prescribed number (usually 8) of dummy CAS-before-RAS refresh cycles. As the bus
state controller does not perform any special operations for a power-on reset, the necessary power-
on sequence must be carried out by the initialization program executed after a power-on reset.