Rev. 6.0, 07/02, page 815 of 986
Item
Symbol
Min
Typ
Max
Unit
Test Conditions
V
OH
2.4
—
—
V
Output
voltage
All output
pins
V
OL
—
—
0.55
Pull-up
resistance
All pull-up
resistance
R
pull
20
60
180
k
Ω
Pin
capacitance
All pins
C
L
—
—
10
pF
Notes: 1. Connect V
DD-PLL1/2
, V
DD-RTC
, and V
DD-CPG
to V
DDQ
, and connect V
SS-CPG
, V
SS-PLL1/2
, and V
SS-RTC
to
GND, regardless of whether or not the PLL circuits and RTC are used.
2. The current dissipation values are for V
IH
min = V
DDQ
– 0.5 V and V
IL
max = 0.5 V with all
output pins unloaded.
3. I
DDQ
is the total current value for the 3.3 V versions of V
DDQ
, V
DD-PLL1/2
, V
DD-RTC
, and V
DD-CPG
.
*
1 RCR2.RTCEN must be set to 1 to reduce the leak current in the standby mode. (There
is no need to input a clock from EXTAL2.)
*
2 RTCON refers to the status in which RCR2.RTCEN is set to 1 and a clock is being input
to EXTAL2.
Содержание SH7750 series
Страница 106: ...Rev 6 0 07 02 page 56 of 986 ...
Страница 144: ...Rev 6 0 07 02 page 94 of 986 ...
Страница 242: ...Rev 6 0 07 02 page 192 of 986 ...
Страница 270: ...Rev 6 0 07 02 page 220 of 986 ...
Страница 360: ...Rev 6 0 07 02 page 310 of 986 ...
Страница 538: ...Rev 6 0 07 02 page 488 of 986 ...
Страница 706: ...Rev 6 0 07 02 page 656 of 986 ...
Страница 752: ...Rev 6 0 07 02 page 702 of 986 ...
Страница 780: ...Rev 6 0 07 02 page 730 of 986 ...
Страница 822: ...Rev 6 0 07 02 page 772 of 986 ...
Страница 986: ...Rev 6 0 07 02 page 936 of 986 ...
Страница 1030: ...Rev 6 0 07 02 page 980 of 986 ...
Страница 1036: ...Rev 6 0 07 02 page 986 of 986 ...