Device Security
[ Device Security > Management Access > CLI ]
93
RM GUI GRS
Release
8.0
09/2019
Buttons
You find the description of the standard buttons in section
[
Login banner
]
In this tab, you replace the start screen of the Command Line Interface with your own text.
In the default setting, the start screen displays information about the device, such as the software
version and the device settings. With the function in this tab, you deactivate this information and
replace it with an individually specified text.
To display your own text in the Command Line Interface and in the Graphical User Interface before
the login, you use the
Device Security > Pre-login Banner
dialog.
Operation
Operation
Enables/disables the
Login banner
function.
Possible values:
On
The
Login banner
function is enabled.
The device displays the text information specified in the
Banner text
field to the users that login
to the device using the Command Line Interface.
Off
(default setting)
The
Login banner
function is disabled.
The start screen displays information about the device. The text information in the
Banner text
field is kept.
Banner text
Banner text
Specifies the character string that the device displays in the Command Line Interface at the start of
every session.
Possible values:
Alphanumeric ASCII character string with 0..1024 characters
(
0x20..0x7E
) including space characters
<Tab>
<Line break>
Remaining characters
Displays how many characters are still remaining in the
Banner text
field for the text information.
Содержание GREYHOUND GRS1020
Страница 8: ......
Страница 16: ......
Страница 146: ......
Страница 232: ......
Страница 310: ......
Страница 330: ......
Страница 338: ...Readers Comments 337 RM GUI GRS Release 8 0 09 2019 ...
Страница 339: ......
Страница 340: ......
Страница 350: ......
Страница 354: ......
Страница 617: ...Readers Comments 277 UM Config GRS Release 8 0 09 2019 ...
Страница 618: ......
Страница 619: ......