Diagnostics
[ Diagnostics > Status Configuration > Security Status ]
243
RM GUI GRS
Release
8.0
09/2019
Modbus TCP active
Activates/deactivates the monitoring of the
Modbus TCP
function.
Possible values:
marked
(default setting)
Monitoring is active.
If you enable the
Modbus TCP
function, then in the
Security status
frame, the value changes to
error
.
unmarked
Monitoring is inactive.
You enable/disable the
Modbus TCP
function in the
Advanced > Industrial Protocols > Modbus TCP
dialog,
Operation
frame.
Self-signed HTTPS certificate present
Activates/deactivates the monitoring of the HTTPS certificate.
Possible values:
marked
(default setting)
Monitoring is active.
If the HTTPS server uses a self-created digital certificate, then in the
Security status
frame, the
value changes to
error
.
unmarked
Monitoring is inactive.
Buttons
You find the description of the standard buttons in section
[
Port
]
Table
Port
Displays the port number.
Link interrupted on enabled device ports
Activates/deactivates the monitoring of the link on the active ports.