PW3390 Power Analyzer Communication Command Instruction Manual Second Edition
89/107
Setting and Querying Delimiter for CSV File
Syntax
Command
:SAVE:SEParator <CSV/SSV>
Query
:SAVE:SEParator?
Response
CSV:
Comma-
delimited “,”, period-decimal”.”
SSV:
Semicolon-
delimited”;”, comma-decimal”,”
Description
Command
Sets a type of delimiter for CSV file.
Query
Returns a type of delimiter for CSV file.
Example
Command
:SAVE:SEP SSV
Query
:SAVE:SEP?
Response
:SAVE:SEPARATOR SSV (WHEN HEADER IS ON)
SSV (WHEN HEADER IS OFF)
Set and Query CT Ratio
Syntax
Command
:SCALe[CH]:CT <CTRatio>
Query
:SCALe[CH]:CT?
[CH]
・・・・
1,2,3,4
Response
CT Ratio :0000.01 to 9999.99
Description
Command
Sets the CT ratio of the specified channel.
Query
Returns the setting for the CT ratio of the specified channel in numerical
value.
Example
Command
:SCAL1:CT 2.0
Set the CT ratio of Channel 1 to 2.0.
Query
:SCAL1:CT?
Response
:SCALE1:CT 0002.00 (WHEN HEADER IS ON)
0002.00 (WHEN HEADER IS OFF)
Note
The setting for CT Ratio OFF is 1.0. The Query Response for OFF is 0001.00.
Settings for the other channels in the measurement line combination will also be changed.
Specify the first channel in the combination channels.