PW3390 Power Analyzer Communication Command Instruction Manual Second Edition
35/107
Set and Query Saved Items of Integration Values
Syntax
Command
:DATAout:ITEM:INTEGrate <PIH>,<MIH>,<IH>,<PWP>,<MWP>,<WP>,
<PWP_SUM>,<MWP_SUM>,<WP_SUM>,<Elapsed time>
Query
:DATAout:ITEM:INTEGrate?
Response
<PIH>,<MIH>,<IH>,<PWP)>,<MWP>,<WP>,<PWP_SUM>,<MWP_SUM>,<WP_SUM>,
<Elapsed time>
128
64
32
16
8
4
2
1
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
PIH
-
-
-
-
PIH4
PIH3
PIH2
PIH1
MIH
-
-
-
-
MIH4
MIH3
MIH2
MIH1
IH
-
-
-
-
IH4
IH3
IH2
IH1
PWP
-
-
-
-
PWP4
PWP3
PWP2
PWP1
MWP
-
-
-
-
MWP4
MWP3
MWP2
MWP1
WP
-
-
-
-
WP4
WP3
WP2
WP1
PWP_SUM
-
-
-
-
-
PWP123 PWP34 PWP12
MWP_SUM
-
-
-
-
-
MWP123 MWP34 MWP12
WP_SUM
-
-
-
-
-
WP123
WP34
WP12
Elapsed
time
-
-
-
-
-
-
ms unit
time
Description
Command
Sets the integration value saved items between 0 and 255.
Query
Returns the setting for the integration value saved items with values of 0
and 255.
Example
Command
:DATA:ITEM:INTEG 0,0,0,1,1,1,0,0,0,1
Set all the integration current values and the integration times in Channel 1
to ON.
Query
:DATA:ITEM:INTEG?
Response
:DATAOUT:ITEM:INTEGRATE 0,0,0,1,1,1,0,0,0,1 (WHEN HEADER IS ON)
0,0,0,1,1,1,0,0,0,1 (WHEN HEADER IS OFF)
Note
Some items are unselectable due to the wiring and integration mode.
When an unselectable item is specified, an execution error will occur and other items will also
not be set.
Содержание PW3390