PW3390 Power Analyzer Communication Command Instruction Manual Second Edition
59/107
Set and Query Zero Cross Filter
Syntax
Command
:FILTer <STRONG/WEAK/OFF>
Query
:FILTer?
Response
STRONG:Filter strong
WEAK :Filter weak
OFF
:Filter OFF
Description
Command
Sets the zero cross filter.
Query
Returns the zero cross filter setting as a character string.
Example
Command
:FILT STRONG
Set the zero cross filter to strong.
Query
:FILT?
Response
:FILTER STRONG (WHEN HEADER IS ON)
STRONG (WHEN HEADER IS OFF)
Set and Query Measurement Lower Limit Frequency
Syntax
Command
:FREQuency:LOWer <frequency data>
Query
:FREQuency:LOWer?
Response
<frequency data> :0.5Hz/1Hz/2Hz/5Hz/10Hz/20Hz
Description
Command
Sets the measurement lower limit frequency.
Query
Returns the measurement lower limit frequency setting with a
character string.
Example
Command
:FREQ:LOW 10Hz
Set the measurement lower limit frequency to 10Hz.
Query
:FREQ:LOW?
Response
:FREQUENCY:LOWER 10Hz (WHEN HEADER IS ON)
10Hz (WHEN HEADER IS OFF)