![Hioki PW3390 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/hioki/pw3390/pw3390_instruction-manual_2137353017.webp)
PW3390 Power Analyzer Communication Command Instruction Manual Second Edition
17/107
Setting and Querying Full-scale D/A Output Waveform
Syntax
Command
:AOUT:MONitor:SCALe <1/2>
Query
:AOUT:MONitor:SCALe?
Response
1
:
±
1V f.s.
2
:
±
2V f.s.
Description
Command
Sets full-scale of D/A waveform output.
Query
Returns setting for full-scale of D/A waveform output as a numeric value.
Example
Command
:AOUT:MON:SCAL 1
Query
:AOUT:MON:SCAL?
Response
:AOUT:MONITOR:SCALE 1 (when HEADER is ON)
1 (when HEADER is OFF)
Select and Query Auto Range Limit
Syntax
Command
:AUTOrange <WIDE/NARROW>
Query
:AUTOrange?
Response
<WIDE/NARROW>
WIDE
: Widen the auto range limit.
NARROW
: Narrow the auto range limit.
Description
Command
Selects to widen or narrow the auto range limit.
Query
Returns the auto range limit as words.
Example
Command
:AUTO WIDE
Widen the auto range limit.
Query
:AUTO?
Response
:AUTORANGE WIDE (when HEADER is ON)
WIDE (when HEADER is OFF)