PW3390 Power Analyzer Communication Command Instruction Manual Second Edition
61/107
Set and Query THD Calculation Formula
Syntax
Command
:HARMonic:THD <F/R>
Query
:HARMonic:THD?
Response
F
:THD-F(Fundamental wave standard)
R
:THD-R(Harmonic total value standard)
Description
Command
Sets the THD calculation formula.
Query
Returns the THD calculation formula as a character string.
Example
Command
:HARM:THD F
Set the THD calculation formula setting to THD-F.
Query
:HARM:THD?
Response
:HARMONIC:THD F (WHEN HEADER IS ON)
F (WHEN HEADER IS OFF)
Set and Query Header for Response Message
Syntax
Command
:HEADer <ON/OFF>
Query
:HEADer?
Response
ON
: Attach header to the Response message.
OFF
: Do not attach header to the Response message.
Description
Command
Sets header for the Response message.
Query
Returns setting for Response message header as ON or OFF.
Example
Command
:HEAD ON
Attach header to Response message.
Query
:HEAD?
Response
:HEADER ON (WHEN HEADER IS ON)
OFF (WHEN HEADER IS OFF)
Note
When the instrument is turned on, the setting will always return to OFF.
Содержание PW3390
Страница 108: ......