9.1 Connecting to the External Control Terminals
157
3
9
C
h
apt
er
9
E
xt
erna
l C
o
n
trol
The external control terminals on the instrument support trigger signal input and out-
put.
External
Control
Chapter 9
ALARM (Output)
A signal is output whenever the alarm
criteria are satisfied (p. 162).
EXT.TRIG (External trigger input)
Input external signals (p. 159).
Top View
GND
(common with instrument ground)
TRIG.OUT (Trigger output)
Output a signal when a trigger
event occurs (p. 160).
9.1 Connecting to the External Control
Terminals
To avoid electrical hazards and damage to the instrument, do
not apply voltage exceeding the rated maximum to the exter-
nal control terminals.
I/O terminals
Maximum input voltage
Input
EXT.TRIG
0 to 7 V DC
Output
TRIG.OUT
30 V DC
5 mA max, 200 mW max
ALARM
To prevent electric shock accidents and damage to the equip-
ment, always observe the following precautions when making
connections to external terminal blocks and external connec-
tors.
• Before making connections, turn off the power on the
instrument and the equipment to connect.
• Do not exceed the specified signal levels for signals sup-
plied to external terminal blocks.
• Ensure that devices and systems to be connected to the
external control terminals are properly isolated.
Содержание LR8432-20
Страница 1: ...EN LR8432 20 HEAT FLOW LOGGER Instruction Manual Jan 2016 Edition 1 LR8432B980 00 16 01H...
Страница 2: ......
Страница 22: ...Operating Precautions 14...
Страница 50: ...2 5 Zero Adjustment 42...
Страница 88: ...3 7 Viewing All Channel Settings in a List 80...
Страница 104: ...4 5 About Recording Operation 96...
Страница 154: ...7 4 Waveform Calculation Formula 146...
Страница 164: ...8 3 Making System Settings 156...
Страница 232: ...Appendix 12 Heat Flow A44...
Страница 236: ...Index Index 4...
Страница 237: ......
Страница 238: ......