18.3 Error Messages
317
Chapte
r 18
Main
tenanc
e and
Ser
vi
ce
14
18
54
Cannot use.(Overlay)
The overlay function is not available when us-
ing the Roll mode.
"8.3 Displaying New Wave-
forms Over Past Waveforms
(Overlay)" (
55
Cannot use. (Overlay, Memory Division,
Wave Calculation)
If roll mode is used, these functions cannot be
used.
"8.2 Displaying Waveforms
During Recording (Roll
Mode)" (
56
Real-time printing is not available.
Recording Length (Shot) is set to Continuous
(Cont.). Real-time printing is not available
when using the Recorder function and Fast
timebase setting.
"3.4.3 Recording Length
(number of divisions)" (
p.46)
"6.2 Making Auto Print Set-
tings" (
57
Cannot set.(External sampling)
Cannot use roll mode when using external
sampling.
"8.2 Displaying Waveforms
During Recording (Roll
Mode)" (
58
Rated capacity/rated output error.
Rated capacity/Rated output has exceeded
selected range. Input correct value.
Note (
59
Cannot use. (Roll Mode, Wave Calcula-
tion)
If the memory division function is used, these
functions cannot be used.
60
No waveform data.
Acquire waveform data.
-
65
When sampling rate is 1 ms/S, line inter-
polation is not available.
Select a slower sampling rate setting.
"4.2 Setting Measurement
Configuration" (
68
Recording length is too long.
Shorten the measurement record length.
(The maximum record length that can be cal-
culated is 10,000 div.)
"3.4.3 Recording Length
(number of divisions)" (
80
In key lock.
Keylock is engaged. Cancel the Key-Lock
function.
91
LAN: Bad IP address.
Check the IP address.
"15.1 LAN Settings and
Connection (Before Using
FTP/Internet Browser/Com-
mand Communications)"
(
95
LAN: Connection timed out.
Check the transmission setting.
97
LAN: Network error.
Check the connections between the instru-
ment and connection destination.
99
LAN: DHCP failed.
Check the DHCP server.
100
Inappropriate setting of time axis for
waveform data.
Return the time axis to the time axis setting
when the waveform was measured.
"3.4.2 Time Axis Range and
Sampling Rate" (
"9.11 Using trigger settings
to search measurement da-
ta" (
101
Some blocks are different in time axis
setting from the others.
Set the same time axis setting for all search
target blocks.
If they cannot be the same, set the search
range to display blocks only.
102
Some blocks are different in units con-
figuration from the others.
Unify the unit configuration of search target
blocks.
If they cannot be the same, set the search
range to display blocks only.
"9.11 Using trigger settings
to search measurement da-
ta" (
103
No data matching your search condi-
tion.
Check the trigger setting.
104
There is no data in the search target
channel.
Select channels with measurement data in the
inspection target.
105
There is a block with no data in the
search target channel.
Select blocks with measurement data in the
inspection target.
Displayed Warnings
Msg
No.
Message
Remedial Action
Reference
Содержание 8847
Страница 1: ...MEMORY HiCORDER Instruction Manual 8847 December 2010 Revised edition 4 8847A981 04 10 12H ...
Страница 2: ......
Страница 18: ...Operating Precautions 8 ...
Страница 26: ...1 4 Basic Key Operations 16 ...
Страница 74: ...4 4 Waveform Observation 64 ...
Страница 98: ...5 5 Managing Files 88 ...
Страница 110: ...6 6 Miscellaneous Printing Functions 100 ...
Страница 126: ...7 8 Seeing Block Waveforms 116 ...
Страница 160: ...8 10 Making Detailed Settings for Input Modules 150 ...
Страница 198: ...10 6 Numerical Calculation Type and Description 188 ...
Страница 296: ...15 7 Controlling the Instrument with Command Communications LAN USB 286 ...
Страница 304: ...16 2 External I O 294 ...
Страница 362: ...Appendix 5 FFT Definitions A28 ...
Страница 368: ...Index Index 6 ...
Страница 369: ......
Страница 370: ......
Страница 371: ......