11.1 Waveform Calculation Workflow
191
11
Chapte
r 1
1
W
a
vef
o
rm C
a
lcul
at
io
n
Func
ti
ons
Applying Calculations to Existing Data
After measurement with calcula-
tion OFF (Or with data loading)
(To load measurement data from storage media for calcu-
lation)
Make Calculation Settings
Make calculation settings on the Waveform Calculation
sheet (
[Wave Calc]
sheet)
Execute Calculation
Select [Exec] to execute calculations.
(To interrupt calculations, press the
STOP
key)
Display Calculation Results
Results are displayed on the Waveform screen.
(Print or Save)
Print or save calculation results as occasion demands.
• Print:
key
• Save:
SAVE
key
• The maximum record length that can be calculated is 10,000 div.
To perform calculation for waveforms measured at longer record lengths, save
to files in sections at a range shorter than 10,000 div, reload to this instrument
and then calculate.
• When memory division is not used, it is possible to reference the last 16 mea-
sured waveforms. However, when waveform calculation is performed for this
waveform, waveform data other than that of the currently referenced blocks
(the blocks in the data to be calculated) is deleted.
When specifying a waveform range for calculation:
Before executing a calculation, specify the calculation range using the A/B cursors
(div or Trace cursors) on the Waveform screen. Set the calculation range on the
[Wave Calc]
sheet to
[A-B Wave]
.
• Range cursors cannot be used to specify the range.
• When one cursor is used, the calculation range is from the cursor to the end of
the data.
If waveform calculation is performed after measurement, measured waveforms
with a record length of 10,001 div or more cannot be calculated, even if the range is
specified by the A/B cursor.
See:
"7.2 Specifying a Waveform Range (A/B Cursor)" (
"11.2 Settings for Waveform Calculation" (
Changing calculation settings while measuring:
Changes made to calculation settings while measuring are applied after measure-
ment is finished.
To change calculation settings and recalculate:
Make changes to calculation contents on the
[Wave Calc]
sheet, and execute the
calculation.
See:
"11.2 Settings for Waveform Calculation" (
To not display a calculation waveform, or to display only the desired waveform:
The displayed sheet and calculation waveform to be displayed can be selected on
the
[Wave Calc]
sheet.
See:
"11.2.3 Changing the display method for calculated waveforms" (
Содержание 8847
Страница 1: ...MEMORY HiCORDER Instruction Manual 8847 December 2010 Revised edition 4 8847A981 04 10 12H ...
Страница 2: ......
Страница 18: ...Operating Precautions 8 ...
Страница 26: ...1 4 Basic Key Operations 16 ...
Страница 74: ...4 4 Waveform Observation 64 ...
Страница 98: ...5 5 Managing Files 88 ...
Страница 110: ...6 6 Miscellaneous Printing Functions 100 ...
Страница 126: ...7 8 Seeing Block Waveforms 116 ...
Страница 160: ...8 10 Making Detailed Settings for Input Modules 150 ...
Страница 198: ...10 6 Numerical Calculation Type and Description 188 ...
Страница 296: ...15 7 Controlling the Instrument with Command Communications LAN USB 286 ...
Страница 304: ...16 2 External I O 294 ...
Страница 362: ...Appendix 5 FFT Definitions A28 ...
Страница 368: ...Index Index 6 ...
Страница 369: ......
Страница 370: ......
Страница 371: ......