Section 6
♦
Alarm Descriptions
90
CMN-41 Series Installation and Operation Handbook
Copyright © 2009, Harris Corporation
Table 6-2. Video Alarms Setup Menu
NOTE
: Descriptions for these selection options start on page 94.
Selection
Selection Option
Selection Option
Selection Option
Loss of Carrier
Enable
Duration
0 to 60 seconds
(2 seconds *)
Loss of Reference
Enable
Duration
0 to 60 seconds
(2 seconds *)
Loss of Active Video
Enable
Threshold
0 to 350 mV
(300 mV *)
Sensitivity
2 * to 20 CES
Duration
0 to 60 seconds
(2 seconds *)
Loss of Payload
Identifier
Enable
Duration
0 to 60 seconds
(2 seconds *)
Gamut RGB
Gamut
Upper
Enable
Threshold
650 to 750 mV
(710 mV *)
Sensitivity
1 to 20 CES
(15 CES *)
Duration
0 to 60 seconds
(2 seconds *)
RGB Gamut Lower
Enable
Threshold
–50 to 50 mV
(–10 mV *)
Sensitivity
1 to 20 CES
(15 CES *)
Duration
0 to 60 seconds (2
seconds *)
Luminance
Gamut
Upper
Enable
Threshold 525/59.94
90 to 108 IRE
(105 IRE *)
Threshold 625/50
92 to 109 Units setting
(107 Units *)
Sensitivity
1 to 20 CES
(15 CES *)
Duration
0 to 60 seconds (2
seconds *)
Luminance
Gamut
Lower
Enable
Threshold 525/59.94
1.5 * to 20 IRE
Threshold 625/50
–7 to 20 Units setting
(–4 Units *)
Sensitivity
1 to 20 CES
(15 CES *)
Duration
0 to 60 seconds (2
seconds *)