Section 2
♦
Installation
8
CMN-41 Series Installation and Operation Handbook
Copyright © 2009, Harris Corporation
Rack Mounting the CMN-41
When selecting the permanent mounting location for the CMN-41, make sure that the
flow of air to the ventilation holes on the top and sides of the chassis is not obstructed.
Rack mounting the CMN-41 is illustrated in
Figure 2-1
for the DRT-4 rack mount
case.
Table 2-1
lists the parts required to rack mount the CMN-41 into the DRT-4 rack
mount case.
Figure 2-1. Mounting the CMN-41 in a Rack Using the DRT-4
NOTE
: Although only one CMN-41 unit is shown in Table 2-1, two CMN-41 units may be mounted into a
DRT-4 rack case.
Table 2-1. Parts Required to Rack Mount the CMN-41 Using the DRT-4
Key Item
Number
Qty Description
1 —
A/R CMN-41
unit
2
866080
1
DRT-4 rack tray
3 832072
2 Metal
extension
mount
4
832070
2
Metal extension bracket
5
831030
8
#10-32×¾-in. Phillips head screws
6
831019
4
Nylon washer, rack mount
7 831119
8 #8–32
kep
nuts
8 831131
4 #8–32×
3
/
8
-in. Phillips head screws (CMN mtg)
9
831064
4
#8–32×½-in. Phillips head screws