Section 4
♦
Operating the CMN-41
44
CMN-41 Series Installation and Operation Handbook
Copyright © 2009, Harris Corporation
Placing the Gamut Display in Line Select Mode
Press the LINE button to enable monitoring of a single line of a video
signal. This enables Line Select to monitor individual lines of the entire
image.
To view a line in Line Select mode:
1.
Press the LINE button to place the selected Gamut display in Line Select mode. At
the bottom of the display, the Line number and Odd or Even field appear, as shown
in
Figure 4-24
.
Figure 4-24. Establishing Line Select
NOTE
: In a Progressive (p) format, Odd and Even selections are not available.
2.
Press the Up/Down arrow knob to alternate between the Odd and Even fields for
interlaced formats.
3.
Rotate the Up/Down arrow knob to select the line to be displayed.
Setting Display Options
Press and release the ZOOM button to cycle through the displays of the
Composite or RGB gamut graticule:
•
Expand the center
•
Expand the upper-left quadrant
•
Expand the upper-right quadrant
•
Expand the lower-right quadrant
•
Expand the lower-left quadrant
•
Normal view
Gamut Setup Menu
Press and hold the GMT function button to access the Gamut Setup menu. For more
information on the global Gamut Setup menu, see page 67. For descriptions of Gamut
Setup menu selection options, see page 78.
Picture Display
The Picture Display is used to show the picture of the selected input.
Press and release the PICT function button to display the picture. A
Picture display diagram is shown in
Figure 4-25
and described in
Table
4-8
. Only one picture can be displayed.