Section 4
♦
Operating the CMN-41
30
CMN-41 Series Installation and Operation Handbook
Copyright © 2009, Harris Corporation
Figure 4-6. Establishing the Gain
Selecting Components
Press and release the COMP button to step through single or multiple
components in a signal.
When multiple components are selected, use the H/V button to toggle between 1H and
1V. With only one component selected, press the H/V button to toggle between 1H and
1V, or 2H and 2V.
Selecting Display Options
Press and release the ZOOM button to cycle through these display options:
•
ZOOM positioned on the 0 IRE, 0 mV, or 0% graticule line
•
ZOOM positioned on the 100 IRE or 700 mV, or 100% graticule
line
•
Normal view
At each zoom position, the graticule scale and waveform displays expand to provide
more resolution around the zoom point.
Placing the Waveform Display in Line Select Mode
Press and release the LINE button to enable the monitoring of a single
line of a video signal. To view a line in Line Select mode:
1.
Press the LINE button to place the selected waveform display in Line Select mode.
At the bottom-center of the display, the Line number and the Odd or Even field
appear, as shown in
Figure 4-7
.