Section 4
♦
Operating the CMN-41
CMN-41 Series Installation and Operation Handbook
51
Copyright © 2009, Harris Corporation
Figure 4-31. Six Bar Graph Display Diagram
Table 4-11. Description of Six Bar Graph Display Diagram
Field
Identifier
Field Information
Nomenclature
1
Input
Displays selected input (A or B)
2
Status
Displays audio type as Mute, AES, or Embedded
Displays audio clip or mute alarm indicators
3
Phase Bar (2)
Phase Meter of bar graph 2
4
Channel Number
Shown as 1-16 (AES is 1-2 and Embedded is 1-16)
5
Device
Displays labels for lissajous, bar graphs, and headphone
outputs
6
Phase Bar (3)
Phase Meter of bar graph 3
7
Level Markers
Shows peak and reference levels for the signal; this can be
adjusted in the Audio
→
Meter Setup selection options
8
Zoom
Zoom (when enabled); blank when disabled
9
Scale Selection
Displays the selected meter scale: Type I, Type IIa, Type
IIb, Type I + 8, Nordic, DIN 45406, dBFS, Zero REF dBFS,
Custom dB, and Custom dBFS
10
Meter Response
Displays the selected meter response: VU, Peak, True
Peak, VU + Peak, VU + True Peak, Custom
11 Audio
Graticule
(with
meter labels)
Shown as L1, R1, L2, R2, L3, and R3 (or Custom label)
12
Phase Bar (1)
Phase Meter of bar graph 1