Section 4
♦
Operating the CMN-41
CMN-41 Series Installation and Operation Handbook
49
Copyright © 2009, Harris Corporation
Figure 4-29. Two Bar Graph Display with Lissajous Diagram
Table 4-9. Description of Two Bar Graph Display with Lissajous Diagram
Field
Identifier
Field Information
Nomenclature
1
Input
Displays selected input (A or B)
2
Status
Displays audio type as Mute, AES, or Embedded
Displays audio clip or mute alarm indicators
3
Channel Number
Shown as 1-16 (AES is 1-2 and Embedded is 1-16)
4
Device
Displays labels for lissajous, bar graphs, and headphone
outputs
5
Lissajous Display
Lissajous of bar graph 1 with labels for R, L, and the
number of the meter being monitored (for example, M-1)
6
Zoom
Zoom when enabled; blank when disabled
7
Scale Selection
Displays the selected meter scale: Type I, Type IIa, Type
IIb, Type I + 8, Nordic, DIN 45406, dBFS, Zero REF dBFS,
Custom dB, and Custom dBFS
8
Level Markers
Shows peak levels for the signal; this can be adjusted in
the Audio
→
Meter Setup selection options
9
Meter Response
Displays the selected meter response: VU, Peak, True
Peak, VU + Peak, VU + True Peak, Custom
10 Audio
Graticule
(with
meter labels)
Shown as stereo pairs (L1, R1), SMPTE 320M, or custom
label
11
Phase Bar
Phase Meter of bar graph 1