Section 5
♦
Global Setup Menu Functions
CMN-41 Series Installation and Operation Handbook
73
Copyright © 2009, Harris Corporation
Table 5-16. Unit Configuration Setup Menu
NOTE
: Descriptions for these selection options start on page 83.
Selection Option
Selection Option
Selection Option
Selection Option
GPIO
Input Function
Input 1
Select A
Select
B
User GPI Alarm 1 *
Input
2
Select
A
Select
B
User GPI Alarm 2 *
Input 3
Recall Preset 1
Recall
Preset
2
User GPI Alarm 3 *
Input 4
Recall Preset 3
Recall
Preset
4
User GPI Alarm 4 *
Output Function
Polarity
Normally Open *
Normally
Closed
Setup
Follow
Input
A
Follow
Input
B
Follow Alarms *
IP Configuration
Ethernet Config Screen
System Time
Time Setup Screen
Show Clock *
Flash Update From
USB
File Navigator Screen
Feature Upgrade From
USB
File Navigator Screen
About About
Screen
Video Setup Menu Selection Options
The Video Setup selection options are used to automatically or manually select the
video format reference standard for the SDI input. The format selection determines the
unit of measure and the critical amplitude limits for the input. The Video Setup
selection options are described below.
•
Auto Detect
: This selection option is used to automatically detect the format of the
input signal. This is the default setting.
•
1080i
: This selection option is used force the unit into 1080 interlaced video mode.
•
1080i Frame Rate
: This selection option is used to set up the 1080i frame rate.
Selection options are 60, 59.94, and 50. The default setting is 59.94.
•
1080p
: This selection option is used to force the unit into 1080 progressive video
mode.
•
1080p Frame Rate
: This selection option is used to set up the 1080p frame rate.
Selection options are 60, 59.94, 50, 30, 29.97, 25, 24, and 23.98. The default setting
is 59.94.