112
Chapter
5
•
•
•
•
•
•
RANGE: 0-5 (default 2) Not to exceed 1 part in 100,000
On the W
eb page
, from the Decimal Point pull-down list, select the decimal position for
this instrument.
On the
HI 6500 series instrument display
, select the Setup menu and use the UP or
DOWN button to select the Decimal Point menu item. The list of decimal point values
supported will be displayed and the current value will be highlighted, if the decimal point
needs to be modified use the UP and DOWN buttons to select a new value and press the
ENTER button.
Graduation Size Parameter
The Graduation Size is the Minimum increment displayed by the instrument. The Base
Graduation Number can be calculated by dividing the Total Load Cell Capacity by 10,000.
For example, with two decimal points selected, a graduation size of 10 will display
increments of .10 units and the graduation size .50 will display increments of.50 units. For
a scale with 10,000 capacity, graduation size = 1
RANGE: 1, 2, 5,10, 20, 50, 10, 200, 500, 1000 (default 1)
On the
Web page
, from the Grads pull-down menu, select a Graduation Size Parameter for
this instrument.
Содержание HI 6500 Series
Страница 10: ...viii Contents ...
Страница 20: ...10 Chapter 2 ...
Страница 72: ...62 Chapter 4 ...
Страница 96: ...86 Chapter 5 Profibus DP Commands and Parameters ...
Страница 97: ...Instrument Configuration 87 Serial Option Termination ...
Страница 126: ...116 Chapter 5 ...
Страница 156: ...146 Chapter 8 ...
Страница 163: ...Troubleshooting 153 General Troubleshooting Flow Chart Index ...
Страница 164: ...154 Chapter 9 A Guideline Instability Electrical and Mechanical review ...
Страница 165: ...Troubleshooting 155 A1 Checking for Unstable Components in a Weighing System ...
Страница 166: ...156 Chapter 9 B Guidelines for Electrical Mechanical or Configuration Issues ...
Страница 167: ...Troubleshooting 157 B1 Guidelines to Verify Electrical Installation ...
Страница 168: ...158 Chapter 9 B2 Guidelines to Verify Mechanical Installation ...
Страница 169: ...Troubleshooting 159 B3 Guidelines to Verify Configuration Filter Settings to Improve Stability ...
Страница 170: ...160 Chapter 9 C Integrated Technician and Stability Test Overview ...
Страница 171: ...Troubleshooting 161 E Testing for Non Return to Zero System with IT Summing Card ...
Страница 173: ...Troubleshooting 163 G Calibration Errors When Performing the Calibration ...
Страница 174: ...164 Chapter 9 H Mechanical Installation ...
Страница 175: ...Troubleshooting 165 J Electrical Inspection ...
Страница 176: ...166 Chapter 9 K Installation Check Points ...
Страница 177: ...Troubleshooting 167 M Weight Processor s Front Display is Blank or Locked ...
Страница 178: ...168 Chapter 9 N Analog Out HI 6510 Only ...
Страница 194: ...184 Appendix A Figure D1 Assembling the Swivel Mount Enclosure on the instrument pedestal ...
Страница 195: ...Installation of Swivel Mount Enclosures 185 Figure D2 Assembling the Swivel Mount Enclosure on a Table ...
Страница 196: ...186 Appendix A Dimensions ...
Страница 200: ...4 HI 6500 Series USER GUIDE Index ...
Страница 201: ......