76
[28, 29] High/low pressure sensor failure
Reconnect
If sensor terminal is fixed well
If voltage between red
terminal and black terminal is 5V
when testing pressure sensor by
multimeter
If voltage between white terminal and
black terminal is 0.5V~3.5V when
testing pressure sensor
by multimeter
Replace connecting board
Replace PCB
Replace pressure sensor
N
Y
Y
N
N
Y
Содержание AU082FYCRA(HW)
Страница 1: ...ATW Service Manual SYJS 03 2019REV A Edition 2019 03 ...
Страница 11: ...9 405 410 600 174 174 450 950 965 395 6 Dimensions AU082FYCRA HW Unit mm ...
Страница 12: ...10 AU112 162FYCRA HW Unit mm 1490 950 380 187 405 410 600 174 174 450 170 ...
Страница 13: ...11 AU082FYCRA HW 7 Piping Diagram ...
Страница 14: ...12 AU112 162FYCRA HW ...
Страница 27: ...25 12 Water Pressure Drop ...
Страница 28: ...26 ...
Страница 57: ...55 15 PCB Photo BM2 BM1 PCB code 0151800423 ...