66
(4) If there is no reply from the air-condition, theparemeter display will be “ --”. If the communication returns that
defrost, check or antifreeze is running, relevant icon will dispaly
Category Function code
Function description
Set/ Query
A
00
ON/OFF
Can be queried and set
A
01
Setting mode
Can be queried and set
A
02
temperature setting
Can be queried and set
A
03
Temperature compensation
Can be queried and set
A
04
Electric heating
Can be queried and set
A
05
Pump
Can be queried and set
A
06
Centralized controller group number
Can be queried and set
A
07
Rust prevention operation
Can be queried and set
A
08
Floor dry
Query only
A
09
Check 1
Can be queried and set
A
0A
Check 2
Can be queried and set
A
0B-3F Reserved
Reserved function, does not participate in the loop when
the function code loops
Can be queried and set
A
40
Type of heat exchange unit
Query only
A
41
Operation mode
Query only
A
42
Antifreeze
Query only
A
43
Rust prevention operation
Query only
A
44
Defrost
Query only
A
45
Current fault
Query only
A
46
Number of connected indoor controllers
Query only
A
47
Number of connected indoor controllers that is on.
Query only
A
48
Number of connected indoor controllers that is thermo.
on.
Query only
A
49
Power
Query only
A
4A
Electric heating state
Query only
A
4B
Pump state
Query only
A
4C
Micro switch
Query only
Содержание AU082FYCRA(HW)
Страница 1: ...ATW Service Manual SYJS 03 2019REV A Edition 2019 03 ...
Страница 11: ...9 405 410 600 174 174 450 950 965 395 6 Dimensions AU082FYCRA HW Unit mm ...
Страница 12: ...10 AU112 162FYCRA HW Unit mm 1490 950 380 187 405 410 600 174 174 450 170 ...
Страница 13: ...11 AU082FYCRA HW 7 Piping Diagram ...
Страница 14: ...12 AU112 162FYCRA HW ...
Страница 27: ...25 12 Water Pressure Drop ...
Страница 28: ...26 ...
Страница 57: ...55 15 PCB Photo BM2 BM1 PCB code 0151800423 ...