75
LED displays 08E/10E
System water flow protection or
anti-idling protection for
water pump
Whether system water flow
leaks.
Whether the water pipe is too
long and not connected to
water pump.
Whether water pressure
difference switch is damaged.
Remove the water pressure
difference switch and close the fin
manually to check whether
malfunction still exists
Whether water system is
stuck
Whether water pump is damaged
Repair the leaks and add
the water again.
To configure external
water
pump
Wash or replace the stuck
components and pipeline.
Replace water pump.
Replace water pressure difference switch.
Malfunction still exists
Replace main PCB
N
Y
N
N
N
N
N
N
Y
Y
Y
Y
Y
08,10: System water flow protection