64
Note:
1. Setting range:
1) Tank mode: 25°C~75°C (the default is 42°C).
2) Cooling mode of air conditioning: water temperature 5°C~20°C (the default is 9°C).
3) Heating mode of air conditioning: water temperature 25°C~55°C (the default is 40°C).Setting accuracy is 0.5°C.
2. Outlet water temperature display range: 0°C~100°C,display accuracy is 0.1°C.
3. The controller has two kinds of main display interface, standard version and simple version. The simple version
has no timer, week, clock.If you want to change the interface,you need to change the DIP switch(SW1-6) of the
wired controller,and it willbe effective after the system is powered again.
19.3 Operation
(1)Basic function description
(2)Special function index
Basic function
description
Method of operation
ON/OFF
Press the key
to switch on/off the wired controller.
Mode control
In the state of on, press the key
to change mode.
Whether there is “tank” mode or not depends on the indoor unit setting.
Adjusting setting
temperature
In the state of on,press the key
or
to adjust the setting temperature.
Function
Method of operation
Forced
to start
pump (for
debugging)
In the state of off, long press the key
for 15 seconds.
Set backlight
time
In the state of off, press the key
and
for 5 seconds, 00 (stable lighting) /15S/30S/60S. Adjust
the value by pressing the key or
and confirm by pressing the key
.
Timer mode Press the key
for 5 seconds to enter the timer ON/OFF setting, choose ON/OFF by pressing the
key or
and press the
to confirm.
Time setting Press the key for 10 seconds to enter into time setting function.
Function
Method of operation
Set parameter of timer
In the state of ON, long press the key
and for 5 seconds to enter.
Check parameters and
change functions (for
debugging)
When the backlight is on, press the key
and for 5 seconds to enter.
Set and cancel child lock Press the key and
for 10 seconds to set or cancel.
ECO(default)
/QUIET/TURBO
In the state of on, press the key to enter, switch by pressing the key
or
, and
confirm by pressing the key
again.
Содержание AU082FYCRA(HW)
Страница 1: ...ATW Service Manual SYJS 03 2019REV A Edition 2019 03 ...
Страница 11: ...9 405 410 600 174 174 450 950 965 395 6 Dimensions AU082FYCRA HW Unit mm ...
Страница 12: ...10 AU112 162FYCRA HW Unit mm 1490 950 380 187 405 410 600 174 174 450 170 ...
Страница 13: ...11 AU082FYCRA HW 7 Piping Diagram ...
Страница 14: ...12 AU112 162FYCRA HW ...
Страница 27: ...25 12 Water Pressure Drop ...
Страница 28: ...26 ...
Страница 57: ...55 15 PCB Photo BM2 BM1 PCB code 0151800423 ...