1-7
BPDU Tunneling for PVST Configuration Example
Network requirements
As shown in
:
z
CE 1 and CE 2 are edges devices on the geographically dispersed network of User A; PE 1 and PE
2 are edge devices on the service provider network.
z
All ports that connect service provider devices and customer devices and those that interconnect
service provider devices are trunk ports and allow packets of any VLAN to pass through.
z
PVST is enabled for VLANs 1 through 4094 on User A’s network. It is required that, after the
configuration, CE 1 and CE 2 implement consistent PVST calculation across the service provider
network, and that the destination multicast MAC address carried in BPDUs be
0x0100-0CCD-CDD0.
Figure 1-4
Network diagram for configuring BPDU tunneling for PVST
Configuration procedure
1) Configuration on PE 1
# Configure the destination multicast MAC address for BPDUs as 0x0100-0CCD-CDD0.
<PE1> system-view
[PE1] bpdu-tunnel tunnel-dmac 0100-0ccd-cdd0
# Configure GigabitEthernet 1/0/1 as a trunk port and assign it to all VLANs.
[PE1] interface gigabitethernet 1/0/1
[PE1-GigabitEthernet1/0/1] port link-type trunk
[PE1-GigabitEthernet1/0/1] port trunk permit vlan all
# Disable STP on GigabitEthernet 1/0/1, and then enable BPDU tunneling for STP and PVST on it.
[PE1-GigabitEthernet1/0/1] undo stp enable
[PE1-GigabitEthernet1/0/1] bpdu-tunnel dot1q stp
[PE1-GigabitEthernet1/0/1] bpdu-tunnel dot1q pvst
2) Configuration on PE 2
# Configure the destination multicast MAC address for BPDUs as 0x0100-0CCD-CDD0.
<PE2> system-view
[PE2] bpdu-tunnel tunnel-dmac 0100-0ccd-cdd0
# Configure GigabitEthernet 1/0/2 as a trunk port and assign it to all VLANs.
Содержание S5120-EI Series
Страница 139: ...ii...
Страница 268: ...3 3 SwitchB system view SwitchB interface vlan interface 1 SwitchB Vlan interface1 ip address dhcp alloc...
Страница 328: ...i Table of Contents 1 Dual Stack Configuration 1 1 Dual Stack Overview 1 1 Configuring Dual Stack 1 1...
Страница 578: ...1 21 C...
Страница 739: ...1 12 Enable ARP detection based on 802 1X security entries SwitchB arp detection mode dot1x...
Страница 926: ...2 8...
Страница 942: ...ii Single Device Upgrade 3 4 IRF System Upgrade 3 5...
Страница 985: ...1 1...
Страница 1018: ...1 6...