12. Network Settings
12.1. Configuring the General Settings
The network settings must be properly configured before you operate the NVR/DVR over the network.
Steps:
1. Enter the Network Settings interface: Menu> Con
fi
guration> Network
2. Select the “General” tab.
3. In the “General Settings” interface, you can con
fi
gure the following settings: Working Mode, NIC Type, IPv4
Address, IPv4 Gateway, MTU and DNS Server. If the DHCP server is available, you can click the checkbox of
“DHCP” to automatically obtain an IP address and other network settings from that server.
Working Mode:
Four 10M/100M/1000M NIC cards are provided and it allows the device to work in the Multi-address, Load
Balance and Net fault-tolerance modes.
Multi-address Mode:
The parameters of the four NIC cards can be configured independently. You can select a LAN in the NIC type field
for parameter settings. You can select one NIC card as default route. And then the system is connecting with the
extranet the data will be forwarded through the default route.