-26-
Model G0634Z/G0634XP (Mfd. Since 01/20)
Test Run
Once assembly is complete, test run the machine
to ensure it is properly connected to power and
safety components are functioning correctly.
If you find an unusual problem during the test run,
immediately stop the machine, disconnect it from
power, and fix the problem BEFORE operating the
machine again. The
Troubleshooting table in the
SERVICE section of this manual can help.
DO NOT start machine until all preceding
setup instructions have been performed.
Operating an improperly set up machine
may result in malfunction or unexpect-
ed results that can lead to serious injury,
death, or machine/property damage.
Serious injury or death can result from
using this machine BEFORE understanding
its controls and related safety information.
DO NOT operate, or allow others to operate,
machine until the information is understood.
To test run machine:
1.
Clear all setup tools away from machine.
2.
Press Emergency Stop button in.
3.
Make sure jointer tables are folded down and
locked in place (see
Page 37
).
4.
Connect machine to power by inserting power
cord plug into a matching receptacle.
5.
Twist Emergency Stop button clockwise until
it springs out (see
Figure 26
). This resets the
switch so the machine can start.
6.
Press ON button to turn machine
ON
. Verify
motor starts up and runs smoothly without
any unusual problems or noises.
7.
Press Emergency Stop button to turn machine
OFF
.
8.
WITHOUT resetting Emergency Stop button,
try to start machine by pressing the ON but-
ton. The machine should not start.
— If the machine
does not
start, the safety
feature of the Emergency Stop button is
working correctly.
— If the machine
does
start, immediately
turn it
OFF
and disconnect power. The
safety feature of the Emergency Stop but-
ton is NOT working properly and must be
replaced before further using the machine.
9.
Press ON button, then immediately press
the OFF button on the magnetic switch (see
Figure 1
on
Page 4
).
— If the machine turns
OFF
, the OFF button
is working correctly. The Test Run is com-
plete.
— If the machine does not stop, disconnect
power to the machine. The OFF but-
ton is not working correctly. This feature
must work properly and must be replaced
before further using the machine.
Figure 26.
Resetting the switch.
The Test Run consists of verifying the following:
1) The motor powers up and runs correctly,
2) the OFF button works correctly, and
3) the Emergency Stop Button works correctly.