263
Detail program description - Servo test
Servo test
Function test of Servo 1 … 16
Use the selection keys on the left or right touch pad
to scroll to the menu option »
Servo test
« menu
option in the multi-function menu:
Teacher / pupil
Tx. output swap
Profi trim
Trim memor y
Telemetr y
Channel sequence
Multichannel
Ring limiter
Mp3 player
Basic settings
Ser vo display
Ser vo test
Tap briefl y on the center
SET
key of the right touch
pad to open this menu option:
S E R V O T E S T
activ
off
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
: 0.5s
Any of the inputs 1 … 16 can be activated for the servo
test by selecting with the selection keys of the left or
right touch pad and then briefl y tapping the
SET
key of
the right touch pad. As soon as you have set only one
of the inputs 1 … 16 to "active", the following notice
appears at the bottom of the display screen:
S E R V O T E S T
activ
off
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
: 0.5s
CLR = act./deact.
A simultaneous tap on the
cd
or
ef
selection keys
of the right touch pad (
CLEAR
) would now start and
stop, for example, a servo test of input "1" with a
cycle time of 0.5 s.
To change cycle time, select the loop symbol at the
bottom right of the display with the selection keys of
the left or right touch pad.
S E R V O T E S T
activ
off
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
: 0.5s
CLR = act./deact.
Once this value fi eld has been activated with a brief
tap on the center
SET
key of the right touch pad …
S E R V O T E S T
activ
off
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
CLR = act./deact.
:
0.5s
… the motion cycle can be changed for the value fi eld
shown in inverse video within a range of 0.5 s and
3.0 s in 0.5 s increments. Briefl y tap the center
SET
key of the right touch pad to close time selection.
Important notice:
The shut-off of the transmitter does not
automatically end an active servo test. Therefore,
always stop a servo test manually BEFORE
SHUTTING OFF the transmitter, because the
servo test is otherwise restarted after switching
on the transmitter again.
S E R V O T E S T
activ
off
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
CLR = act./deact.
: 2.5s
The "servo test" function, started with a simultaneous
tap on the
cd
or
ef
selection keys of the right
touch pad (
CLEAR
), automatically operates the
servos as though the corresponding transmitter
controls were being simultaneously and continuously
moved back and forth between -100 % and +100 %
during the preset time. All active mixing and coupling
functions in the respective model memory, therefore,
are effective and the servos move within the specifi ed
servo paths and servo delimitations.
As soon as the servo test has been started by a
simultaneously tap on the
cd
or
ef
selection keys
of the right touch pad (
CLEAR
) a window will open:
S E R V O T E S T
activ
off
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
CLR = act./deact.
: 2.5s
Ser vo test act.
Another tap simultaneously on the
cd
or
ef
selection keys of the right touch pad (
CLEAR
) will
terminate the test.
Содержание 32032
Страница 1: ...33020 mc 20HoTT 2 en Programming Manual o Pro Pro mc 20 mc 20...
Страница 15: ...15 For your notes...
Страница 21: ......
Страница 27: ...27 For your notes...
Страница 41: ...41 For your notes...
Страница 53: ...53 For your notes...
Страница 59: ...59 For your notes...
Страница 63: ...63 For your notes...
Страница 93: ...93 For your notes...
Страница 97: ...97 For your notes...
Страница 141: ...141 How is a ight phase programmed...
Страница 145: ...145 For your notes...
Страница 155: ...155 For your notes...
Страница 175: ...175 For your notes...
Страница 203: ...203 For your notes...
Страница 219: ...219 For your notes...
Страница 253: ...253 For your notes...
Страница 283: ...283 For your notes...
Страница 321: ...321 For your notes...
Страница 322: ...322 For your notes...
Страница 323: ...323 For your notes...