85
Installation & Service Manual
Ethernet Switch
Ethernet Switch
The Ethernet switch built into the GV K-Frame XP auto-detects speed and polarity, and is
10/100/1000 Mbps capable. Either straight-through or crossover Ethernet cabling can be
used. Available Ethernet connectors may be connected to the Facility LAN or other devices,
as needed. However, should the Frame power down, the internal Ethernet switch will also
power down, interrupting communication to devices connected to that Frame’s internal
Ethernet switch. Only connect devices that are system related.
Customer Supplied Ethernet Routers and Switches
Existing facility Ethernet switches can be used in conjunction with a switcher system. If
connecting to a network area outside that used by the switcher system, use of an
appropriately configured Ethernet Router is strongly advised. This reduces network traffic
on the GV K-Frame XP network and keeps it isolated. Any Ethernet switches added
specifically for use with the switcher system should be 1000 Mbps capable for the most
efficient operation.
Ethernet Specifications
Cables
Type
10BaseT, 100BaseT, 1000BaseT compatible
Category 5 cable, 8 conductor twisted pair
The system will work at lower ratings with reduced
performance. 1000BaseT components are highly
recommended.
Connectors
RJ-45 male connector at each end of cable.
Length
100BaseT, 1000BaseT: 328 ft. (100 m) maximum.
10BaseT: 984 ft. (300 m) maximum.
Use additional switches to exceed maximum cable
runs.
Switch
Speed
10/100/1000 Mbps
Ports
RJ-45 auto-negotiating 10/100/1000 Mbps; number of
ports required is dependent upon system size. Frame
and PCU ports are capable of 1000 Mbps. Using a 1000
Mbps Ethernet switch enhances Image Store transfer
speeds.
Unmanaged
Recommended. Configuration not required, but does
not provide remote monitoring capability.
Managed
May be used. Requires configuration, but offers remote
monitoring capability.
To integrate GV K-Frame XP devices into an existing network, ask the local network
administrator for that network’s subnet mask. Before changing IP addresses always set the
subnet masks of the GV K-Frame XP devices to the mask of the local network.
Содержание KARRERA
Страница 47: ...Installation Service Manual 23 15 RU Dimensions Side View ...
Страница 49: ...Installation Service Manual 25 15RUVideo Processor Views 15 RU Front View withDoor Removed ...
Страница 50: ...Frame Installation 26 15 RU Rear ViewIP Gearbox Conversion 15RU Front View withDoor Removed ...
Страница 52: ...Frame Installation 28 PowerSupplyFrameDimensions TopView ...
Страница 126: ...System Cabling GPI In GPI Out Relay Tally Pin Assignments 102 D 37Female Pin 1 Pin19 Pin 20 Pin 37 Socket Pinout ...
Страница 171: ...Installation Service Manual 147 ...
Страница 204: ...Basic Configuration 180 ...
Страница 208: ...Basic Configuration 184 green ...
Страница 234: ...Basic Configuration 210 ...
Страница 265: ...Installation Service Manual 241 ...
Страница 296: ...External Interfaces 272 PBus and GPI Enables ...
Страница 304: ...External Interfaces 280 About Editor Ports 6 Select the Map Sources button and configure the Switcher Sources ...
Страница 337: ...Installation Service Manual 313 8804_33 Karrera3 ME Panel Open Air Guide Removed Transition Input Board Board Power ...
Страница 366: ...Maintenance 342 ...
Страница 367: ...Installation Service Manual 343 ...
Страница 368: ...Maintenance 344 ...