Connect the Remote Aux Panel to the Switcher IP Network
Connect the Remote Aux Panel to the Switcher IP Network
The Remote Aux panel connects to the switcher via Ethernet over an IP Network. To
connect, add the Remote Aux panel as a switcher node.
1
Select
Eng Setup, Node Settings, Remote Aux IP Network
in the menu.
2
In an unused row, select and enter values for the Aux Panel Name, Remote Aux IP
Address, and Suite number using the pop-up keypads displayed when you select each
data pad.
3
Under Aux Panel Type, select the
Single
data pad as the delegation.
Result: Status indicator LED turns green when connected.
Delegate Control of a Switcher Aux Bus to the Remote Aux Panel
Map the switcher Logical Aux Bus for Remote Aux panel control.
1
Select
Eng Setup, Node Settings, Remote Aux Logical Map
in the menu.
2
Select the remote aux panel under the Remote Aux Panel Name scrolling list on the left.
3
Select a Logical Aux Bus.
Result: The switcher Aux Bus sources can be mapped to and controlled by the Remote
Aux panel.
Map Switcher Sources to Remote Aux Bus Buttons
Map switcher sources to the physical source select buttons on the Remote Aux panel. The
first 25 Buttons will be mapped for the S25. For the S50, the first 25 Unshifted and first 25
Shifted button mappings will be used for a total of 50. However, if the auto-shift feature has
been disabled, 32 unshifted and 32 shifted sources can be mapped (top 25, first seven on
the bottom from left to right).
1
Select
Eng Setup, Node Settings, Remote Aux Button Map
in the menu.
2
Select the remote aux panel under the Remote Aux Panel Name scrolling list on the left.
3
Select a source from the Logical Sources or Fixed Sources columns (right) for your
Remote Aux source select buttons 1-25 in the Unshift column.
4
For the S50 model, select sources for buttons 1-25 in the Shift column.
5
If the auto-shift for the bottom 25 source selection is disabled, select up to 32 shifted
sources.
Result: The mapped switcher Aux Bus sources can be controlled by the Remote Aux
panel.
Содержание KARRERA
Страница 47: ...Installation Service Manual 23 15 RU Dimensions Side View ...
Страница 49: ...Installation Service Manual 25 15RUVideo Processor Views 15 RU Front View withDoor Removed ...
Страница 50: ...Frame Installation 26 15 RU Rear ViewIP Gearbox Conversion 15RU Front View withDoor Removed ...
Страница 52: ...Frame Installation 28 PowerSupplyFrameDimensions TopView ...
Страница 126: ...System Cabling GPI In GPI Out Relay Tally Pin Assignments 102 D 37Female Pin 1 Pin19 Pin 20 Pin 37 Socket Pinout ...
Страница 171: ...Installation Service Manual 147 ...
Страница 204: ...Basic Configuration 180 ...
Страница 208: ...Basic Configuration 184 green ...
Страница 234: ...Basic Configuration 210 ...
Страница 265: ...Installation Service Manual 241 ...
Страница 296: ...External Interfaces 272 PBus and GPI Enables ...
Страница 304: ...External Interfaces 280 About Editor Ports 6 Select the Map Sources button and configure the Switcher Sources ...
Страница 337: ...Installation Service Manual 313 8804_33 Karrera3 ME Panel Open Air Guide Removed Transition Input Board Board Power ...
Страница 366: ...Maintenance 342 ...
Страница 367: ...Installation Service Manual 343 ...
Страница 368: ...Maintenance 344 ...