Configuring Milliseconds Between Takes
Many modern router control systems no longer require a delay, or less delay, between
takes. The GV K-Frame XP can transmit takes with or without delay, however the external
router control system must also support the faster settings.
1
Verify that the external device supports the number of milliseconds between takes to
be configured in the menu.
2
In the Eng Setup, Router menu, select the
50
,
25
, or
0 Milliseconds
Between Takes
button.
Define Routed Source Definitions
The Eng Setup Source Definition menu is used to define routed GV Switcher sources, which
includes specifying which router destination will be associated with each switcher source.
1
Select the
Eng Setup
,
Source Definition
in the menu.
2
Select the source to be configured with the router on the left scrolling list.
3
Select the Video Input data pad and enter the number of the input that will be used
with the router video destination.
4
If the routed source will have an associated key signal, touch the appropriate Key Input
button, then touch the Key Input data pad and enter the number of the input that will
be used with the router key signal destination.
Note:
If you assign a key input, the router system needs to be configured to
switch that key destination along with the video destination. Router levels
can be used to accomplish this.
5
Touch the
Router
type button to identify it as a routed source.
Note:
The adjacent status indicator is green when a router is detected, and
red when there is no response. If red, you should check the GV Switcher or
router system configuration or the physical Ethernet connections.
6
Touch the
Router Destination
data pad to open the Router Destinations menu. The
Video Processor receives a list of destination from the router and displays them on
scrolling list on the left.
Содержание KARRERA
Страница 47: ...Installation Service Manual 23 15 RU Dimensions Side View ...
Страница 49: ...Installation Service Manual 25 15RUVideo Processor Views 15 RU Front View withDoor Removed ...
Страница 50: ...Frame Installation 26 15 RU Rear ViewIP Gearbox Conversion 15RU Front View withDoor Removed ...
Страница 52: ...Frame Installation 28 PowerSupplyFrameDimensions TopView ...
Страница 126: ...System Cabling GPI In GPI Out Relay Tally Pin Assignments 102 D 37Female Pin 1 Pin19 Pin 20 Pin 37 Socket Pinout ...
Страница 171: ...Installation Service Manual 147 ...
Страница 204: ...Basic Configuration 180 ...
Страница 208: ...Basic Configuration 184 green ...
Страница 234: ...Basic Configuration 210 ...
Страница 265: ...Installation Service Manual 241 ...
Страница 296: ...External Interfaces 272 PBus and GPI Enables ...
Страница 304: ...External Interfaces 280 About Editor Ports 6 Select the Map Sources button and configure the Switcher Sources ...
Страница 337: ...Installation Service Manual 313 8804_33 Karrera3 ME Panel Open Air Guide Removed Transition Input Board Board Power ...
Страница 366: ...Maintenance 342 ...
Страница 367: ...Installation Service Manual 343 ...
Страница 368: ...Maintenance 344 ...