Basic Configuration
182
Ethernet Tally Configuration
The GV K-Frame XP system provides all the tally data needed by the Ethernet tally client.
Typically, the only user-defined selection for Ethernet tally from the switcher is the on-air
Program M/E. PGM/PST is the default on-air tally Program M/E, however any licensed M/E
can be defined as Program. Sources are on or off air based on the Program M/E selection.
Configure the On-Air Tally Program M/E
The default on-air Program M/E is PGM/PST.
1
Select
Eng Setup, Switcher Tally, On Air Tally
.
2
Select an available (licensed) M/E as the on-air tally Program M/E, for example ME 1,
ME 2, Aux, etc.
Configure the GV Switcher Ethernet Tally System Interface
The switcher system must be configured to interface with third party Ethernet Tally
systems. An initial tally client port selection can help ensure a successful connection.
1
Configure the Ethernet Tally interface IP Address:
a
In the Eng Setup, Ports & Devices menu, select the
Tally Ports
tab.
b
In the Tally Contribution pane, select an Ethernet Tally IP Address data pad and
enter the IP address for an Ethernet Tally system in the pop-up keypad and press
Enter
.
2
Select the adjacent Enable button (highlights green when on).
Note:
When the connection is enabled, the Connection Status LED turns
green.
3
At the tally client, set the connection to
Port 2012
to establish the initial connection
between the GV Switcher and Ethernet Tally systems.
4
At the tally client, set the connection to
Port 2012
to establish the initial connection
between the GV Switcher and Ethernet Tally systems.
Содержание KARRERA
Страница 47: ...Installation Service Manual 23 15 RU Dimensions Side View ...
Страница 49: ...Installation Service Manual 25 15RUVideo Processor Views 15 RU Front View withDoor Removed ...
Страница 50: ...Frame Installation 26 15 RU Rear ViewIP Gearbox Conversion 15RU Front View withDoor Removed ...
Страница 52: ...Frame Installation 28 PowerSupplyFrameDimensions TopView ...
Страница 126: ...System Cabling GPI In GPI Out Relay Tally Pin Assignments 102 D 37Female Pin 1 Pin19 Pin 20 Pin 37 Socket Pinout ...
Страница 171: ...Installation Service Manual 147 ...
Страница 204: ...Basic Configuration 180 ...
Страница 208: ...Basic Configuration 184 green ...
Страница 234: ...Basic Configuration 210 ...
Страница 265: ...Installation Service Manual 241 ...
Страница 296: ...External Interfaces 272 PBus and GPI Enables ...
Страница 304: ...External Interfaces 280 About Editor Ports 6 Select the Map Sources button and configure the Switcher Sources ...
Страница 337: ...Installation Service Manual 313 8804_33 Karrera3 ME Panel Open Air Guide Removed Transition Input Board Board Power ...
Страница 366: ...Maintenance 342 ...
Страница 367: ...Installation Service Manual 343 ...
Страница 368: ...Maintenance 344 ...