Maintenance
300
GV Korona Joystick Calibration
Lever Arm Calibration Procedure, Transition Area
Note:
Selecting
Exit
cancels the Lever Arm calibration mode and returns
that Transition Area to transition operations, but may leave the Lever Arm in
an un-calibrated state. Complete the entire calibration procedure to ensure
normal operation.
GV Korona Joystick Calibration
1
In any E-MEM area, press
Menu, Page
. This shows a list of menu items that are selected
with the buttons below the display.
2
Select
Calib
(press
7
) to enter calibration mode.
3
Choose the
Joystick
to calibrate (press
Lrn
).
8804_03
1
2
1
2
PVW
Next Exit
1
2
1
2
PVW
Next Exit
Содержание KARRERA
Страница 47: ...Installation Service Manual 23 15 RU Dimensions Side View ...
Страница 49: ...Installation Service Manual 25 15RUVideo Processor Views 15 RU Front View withDoor Removed ...
Страница 50: ...Frame Installation 26 15 RU Rear ViewIP Gearbox Conversion 15RU Front View withDoor Removed ...
Страница 52: ...Frame Installation 28 PowerSupplyFrameDimensions TopView ...
Страница 126: ...System Cabling GPI In GPI Out Relay Tally Pin Assignments 102 D 37Female Pin 1 Pin19 Pin 20 Pin 37 Socket Pinout ...
Страница 171: ...Installation Service Manual 147 ...
Страница 204: ...Basic Configuration 180 ...
Страница 208: ...Basic Configuration 184 green ...
Страница 234: ...Basic Configuration 210 ...
Страница 265: ...Installation Service Manual 241 ...
Страница 296: ...External Interfaces 272 PBus and GPI Enables ...
Страница 304: ...External Interfaces 280 About Editor Ports 6 Select the Map Sources button and configure the Switcher Sources ...
Страница 337: ...Installation Service Manual 313 8804_33 Karrera3 ME Panel Open Air Guide Removed Transition Input Board Board Power ...
Страница 366: ...Maintenance 342 ...
Страница 367: ...Installation Service Manual 343 ...
Страница 368: ...Maintenance 344 ...